These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 9817652)

  • 1. [Measurement of thermal properties of living tissue in vivo].
    Che C; He J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1997 Jun; 14(2):188-92. PubMed ID: 9817652
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of thermal conductivity, thermal diffusivity, and perfusion.
    Yuan DY; Valvano JW; Anderson GT
    Biomed Sci Instrum; 1993; 29():435-42. PubMed ID: 8329624
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel model of the pulse decay method for measurement of local tissue blood perfusion.
    Yang K; Liu W
    Med Eng Phys; 2004 Apr; 26(3):215-23. PubMed ID: 14984843
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of thermal diffusivity of biomaterials by focused ultrasonic beams (thermal pulse decay method by focused ultrasonic beams).
    Nakayama M; Tanishita K
    Biomed Mater Eng; 1994; 4(2):105-14. PubMed ID: 7920196
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Self-heated thermistor measurements of perfusion.
    Anderson GT; Valvano JW; Santos RR
    IEEE Trans Biomed Eng; 1992 Sep; 39(9):877-85. PubMed ID: 1473816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermal diffusion probe and instrument system for tissue blood flow measurements: validation in phantoms and in vivo organs.
    Delhomme G; Newman WH; Roussel B; Jouvet M; Bowman HF; Dittmar A
    IEEE Trans Biomed Eng; 1994 Jul; 41(7):656-62. PubMed ID: 7927386
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A sensitivity analysis of the step-temperature technique for measurement of local tissue blood perfusion.
    Yang K; Liu W
    J Med Eng Technol; 2008; 32(1):73-82. PubMed ID: 18183522
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Investigation of the thermal and tissue injury behaviour in microwave thermal therapy using a porcine kidney model.
    He X; McGee S; Coad JE; Schmidlin F; Iaizzo PA; Swanlund DJ; Kluge S; Rudie E; Bischof JC
    Int J Hyperthermia; 2004 Sep; 20(6):567-93. PubMed ID: 15370815
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of formalin fixation on thermal conductivity of the biological tissue.
    Kharalkar NM; Bauserman SC; Valvano JW
    J Biomech Eng; 2009 Jul; 131(7):074508. PubMed ID: 19640144
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Heat analysis of biological tissue exposed to microwave by using thermal wave model of bio-heat transfer (TWMBT).
    Ozen S; Helhel S; Cerezci O
    Burns; 2008 Feb; 34(1):45-9. PubMed ID: 17624675
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of directional thermal properties of biomaterials.
    Bhavaraju NC; Cao H; Yuan DY; Valvano JW; Webster JG
    IEEE Trans Biomed Eng; 2001 Feb; 48(2):261-7. PubMed ID: 11296882
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of thermal behavior of a biological tissue: an equivalence of Pennes bioheat equation and Wulff continuum model.
    Das K; Mishra SC
    J Therm Biol; 2014 Oct; 45():103-9. PubMed ID: 25436958
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A self-heated thermistor technique to measure effective thermal properties from the tissue surface.
    Patel PA; Valvano JW; Pearce JA; Prahl SA; Denham CR
    J Biomech Eng; 1987 Nov; 109(4):330-5. PubMed ID: 3695434
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effects of probe configuration on the measurement of bio-tissue thermal physical parameters using step-temperature technique].
    Yang K; Liu W; Luo Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):1001-7. PubMed ID: 18027684
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bioheat transfer problem for one-dimensional spherical biological tissues.
    Kengne E; Lakhssassi A
    Math Biosci; 2015 Nov; 269():1-9. PubMed ID: 26327484
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tissue thermal conductivity by magnetic resonance thermometry and focused ultrasound heating.
    Cheng HL; Plewes DB
    J Magn Reson Imaging; 2002 Nov; 16(5):598-609. PubMed ID: 12412038
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dual-phase lag effects on thermal damage to biological tissues caused by laser irradiation.
    Zhou J; Chen JK; Zhang Y
    Comput Biol Med; 2009 Mar; 39(3):286-93. PubMed ID: 19217088
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thermal pulse decay method for simultaneous measurement of local thermal conductivity and blood perfusion: a theoretical analysis.
    Arkin H; Holmes KR; Chen MM; Bottje WG
    J Biomech Eng; 1986 Aug; 108(3):208-14. PubMed ID: 3747464
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Proposed methods for the measurement of regional renal blood flow using heat transfer analysis.
    Adams T; Spielman WS; Holmes KR; Heisey SR; Chen MM
    Ann Biomed Eng; 1985; 13(3-4):237-58. PubMed ID: 3898927
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive method for simultaneously measuring the thermophysical properties and blood perfusion in cylindrically shaped living tissues.
    Yue K; Zhang X; Zuo YY
    Cell Biochem Biophys; 2008; 50(1):41-51. PubMed ID: 18040887
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.