  • 21. Precise robot-assisted guide positioning for distal locking of intramedullary nails.
    Yaniv Z; Joskowicz L
    IEEE Trans Med Imaging; 2005 May; 24(5):624-35. PubMed ID: 15889550
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study.
    Steinberg EL; Blumberg N; Dekel S
    J Biomech; 2005 Jan; 38(1):63-8. PubMed ID: 15519340
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants.
    Füchtmeier B; May R; Hente R; Maghsudi M; Völk M; Hammer J; Nerlich M; Prantl L
    Arch Orthop Trauma Surg; 2007 Aug; 127(6):441-7. PubMed ID: 17457598
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intramedullary pressure and bone marrow fat extravasation in reamed and unreamed femoral nailing.
    Kröpfl A; Davies J; Berger U; Hertz H; Schlag G
    J Orthop Res; 1999 Mar; 17(2):261-8. PubMed ID: 10221844
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Influence of muscular contractions on the stress analysis of distal femoral interlocking nailing.
    Shih KS; Tseng CS; Lee CC; Lin SC
    Clin Biomech (Bristol, Avon); 2008 Jan; 23(1):38-44. PubMed ID: 17945402
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical analysis of titanium elastic nail fixation in a pediatric femur fracture model.
    Li Y; Stabile KJ; Shilt JS
    J Pediatr Orthop; 2008 Dec; 28(8):874-8. PubMed ID: 19034181
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Comparison of a radiation-independent aiming system and free-hand technique for distal locking of unslotted femoral nails].
    Krettek C; Könemann B; Kölbli R; Machreich T; Kromm A; Tscherne H
    Unfallchirurg; 1998 Nov; 101(11):822-9. PubMed ID: 9865164
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Effects of medical robot-assisted surgical navigation system in distal locking of femoral intramedullary nails: an experimental study].
    Wang JQ; Wang JF; Hu L; Su YG; Wang Y; Zhao CP; Zhou L; Wang TM; Wang MY
    Zhonghua Yi Xue Za Zhi; 2006 Mar; 86(9):614-8. PubMed ID: 16681907
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Development of a locking femur nail for mice.
    Holstein JH; Menger MD; Culemann U; Meier C; Pohlemann T
    J Biomech; 2007; 40(1):215-9. PubMed ID: 16376352
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Anatomical structures at risk with the proud retrograde femoral nail.
    Clement H; Heidari N; Kosuge D; Grechenig W; Tesch NP; Weinberg AM
    Arch Orthop Trauma Surg; 2011 Nov; 131(11):1539-44. PubMed ID: 21706305
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Efficacy of an aiming device for the placement of distal interlocking screws in trochanteric fixation nailing.
    Boraiah S; Barker JU; Lorich D
    Arch Orthop Trauma Surg; 2009 Sep; 129(9):1177-82. PubMed ID: 18677491
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [The biomechanical study of rotating-arm self-locking intramedullary nails in comminuted femoral shaft fractures].
    Fang Y; Fu X; Chi L; Wang G; Yang T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):1041-4. PubMed ID: 17121350
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Avoidance of malreduction of proximal femoral shaft fractures with the use of a minimally invasive nail insertion technique (MINIT).
    Russell TA; Mir HR; Stoneback J; Cohen J; Downs B
    J Orthop Trauma; 2008 Jul; 22(6):391-8. PubMed ID: 18594303
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Retrograde femoral nailing: an understanding of the intercondylar insertion site.
    Morgan SJ; Hurley D; Agudelo JF; Meyers T; Lyons R; Parekh A; Smith WR
    J Trauma; 2008 Jan; 64(1):151-4. PubMed ID: 18188114
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails.
    Whatling GM; Nokes LD
    Injury; 2006 Feb; 37(2):109-19. PubMed ID: 16310192
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A new fluoroscopy-free navigation device for distal interlocking screw placement.
    Lee MY; Kuo CH; Hung SS
    J Med Eng Technol; 2008; 32(4):284-95. PubMed ID: 18666008
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
    Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
    Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Computer assisted orthopaedic surgical system for insertion of distal locking screws in intra-medullary nails: a valid and reliable navigation system.
    Malek S; Phillips R; Mohsen A; Viant W; Bielby M; Sherman K
    Int J Med Robot; 2005 Dec; 1(4):34-44. PubMed ID: 17518403
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A biomechanical comparison of unlocked or locked reamed intramedullary nails in the treatment of mid-third simple transverse femoral shaft fractures.
    Wu CC; Tai CL
    Chang Gung Med J; 2006; 29(3):275-82. PubMed ID: 16924889
    [TBL] [Abstract][Full Text] [Related]  