118 related articles for article (PubMed ID: 9825345)
1. Intramyocardial electrogram variability in the monitoring of graft rejection after heart transplantation.
Grasser B; Iberer F; Schreier G; Schaffellner S; Kastner P; Prenner G; Hipmair G; Wasler A; Petutschnigg B; Müller H; Hutten H; Schaldach M; Tscheliessnigg K
Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 2):2345-9. PubMed ID: 9825345
[TBL] [Abstract][Full Text] [Related]
2. Noninvasive rejection monitoring of cardiac transplants using high resolution intramyocardial electrograms: initial US multicenter experience.
Bourge R; Eisen H; Hershberger R; Keller A; Radovancevic B; Schreier G; Kastner P; Hutten H; Wery S; Mehta N
Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 2):2338-44. PubMed ID: 9825344
[TBL] [Abstract][Full Text] [Related]
3. Influence of activation origin, lead number, and lead configuration on the noninvasive electrophysiologic detection of cardiac allograft rejection.
Pirolo JS; Tweddell JS; Brunt EM; Pyo R; Shuman TS; Cox JL; Ferguson TB
Circulation; 1991 Nov; 84(5 Suppl):III344-54. PubMed ID: 1934429
[TBL] [Abstract][Full Text] [Related]
4. Noninvasive monitoring of rejection therapy based on intramyocardial electrograms after orthotopic heart transplantation. Initial experience with 14 cases.
Zupan I; Vrtovec B; Breskvar UD; Gabrijelcic T
Int Immunopharmacol; 2005 Jan; 5(1):59-65. PubMed ID: 15589460
[TBL] [Abstract][Full Text] [Related]
5. Intramyocardial electrograms for the monitoring of allograft rejection after heart transplantation using spontaneous and paced beats.
Auer T; Schreier G; Hutten H; Tscheliessnigg KH; Allmayr T; Grasser B; Iberer F; Wasler A; Petutschnigg B; Müller H
Transplant Proc; 1995 Oct; 27(5):2621-4. PubMed ID: 7482856
[No Abstract] [Full Text] [Related]
6. Paced epimyocardial electrograms for noninvasive rejection monitoring after heart transplantation.
Auer T; Schreier G; Hutten H; Kleinert R; Wasler A; Petutschnigg B; Iberer F; Tscheliessnigg K; Schaldach M
J Heart Lung Transplant; 1996 Oct; 15(10):993-8. PubMed ID: 8913916
[TBL] [Abstract][Full Text] [Related]
7. Introducing a new clinical method for noninvasive rejection monitoring after heart transplantation to clinical practice: analysis of paced intramyocardial electrograms.
Iberer F; Grasser B; Schreier G; Schaffellner S; Prenner G; Allmayer T; Wasler A; Petutschnigg B; Müller H; Kastner P; Schaldach M; Hutten H; Tscheliessnigg KH
Transplant Proc; 1998 May; 30(3):895-9. PubMed ID: 9595139
[No Abstract] [Full Text] [Related]
8. Changes of the intramyocardial electrogram after orthotopic heart transplantation.
Wahlers T; Haverich A; Schäfers HJ; Frimpong-Boateng K; Fieguth HG; Hermann G; Borst HG; Arvanitidou V
J Heart Transplant; 1986; 5(6):450-4. PubMed ID: 3302177
[TBL] [Abstract][Full Text] [Related]
9. Intramyocardial electrograms for non-invasive rejection monitoring: initial experience with an infection-specific parameter.
Grasser B; Iberer F; Schreier G; Allmayer A; Schaffellner S; Prenner G; Wasler A; Petutschnigg B; Müller H; Tscheliessnigg K
Transpl Int; 1998; 11 Suppl 1():S508-11. PubMed ID: 9665047
[TBL] [Abstract][Full Text] [Related]
10. Using intramyocardial electrograms combined with other noninvasive methods for monitoring acute rejection following human heart transplantation.
Jia YX; Meng X; Sun LB; Han J; Chen YT
Chin Med J (Engl); 2009 Jan; 122(2):136-9. PubMed ID: 19187634
[TBL] [Abstract][Full Text] [Related]
11. Noninvasive rejection monitoring after heart transplant.
Iberer F; Grasser B; Schreier G; Prenner G; Schaffellner S; Allmayer T; Wasler A; Petutschnigg B; Müller H; Hutten H; Schaldach M; Tscheliessnigg KH
Transplant Proc; 1997 Nov; 29(7):3126. PubMed ID: 9365694
[No Abstract] [Full Text] [Related]
12. Detection of transplant heart rejection by analysis of endomyocardial voltage.
Arizón del Prado JM; Casares Mediavilla J; González Rodríguez JR; Segura Saint-Gerons C; López Granados A; Romo Peñas E; Concha Ruíz M; Vallés Belsue F
Transplant Proc; 2003 Aug; 35(5):1965-7. PubMed ID: 12962865
[TBL] [Abstract][Full Text] [Related]
13. Diagnosis of early cardiac transplant rejection by fall in evoked T wave amplitude measured using an externalized QT driven rate responsive pacemaker.
Grace AA; Newell SA; Cary NR; Scott JP; Large SR; Wallwork J; Schofield PM
Pacing Clin Electrophysiol; 1991 Jun; 14(6):1024-31. PubMed ID: 1715063
[TBL] [Abstract][Full Text] [Related]
14. Non-invasive cardiac allograft monitoring: the graz experience.
Grasser B; Iberer F; Schreier G; Schaffellner S; Kleinert R; Prenner G; Kastner P; Hutten H; Tscheliessnigg K
J Heart Lung Transplant; 2000 Jul; 19(7):653-9. PubMed ID: 10930814
[TBL] [Abstract][Full Text] [Related]
15. The utility of pacemaker evoked T wave amplitude for the noninvasive diagnosis of cardiac allograft rejection.
Bainbridge AD; Cave M; Newell S; Delaney M; Parameshwar J; Large SR; Wallwork J; Grace AA; Carey NR; Schofield PM
Pacing Clin Electrophysiol; 1999 Jun; 22(6 Pt 1):942-6. PubMed ID: 10392393
[TBL] [Abstract][Full Text] [Related]
16. Heart graft monitoring by the ventricular evoked response.
Mahaux V; Demoulin JC; Biessaux Y; Radermecker M; Schreier G; Limet R; Kulbertus H
Pacing Clin Electrophysiol; 2000 Nov; 23(11 Pt 2):2003-5. PubMed ID: 11139978
[TBL] [Abstract][Full Text] [Related]
17. Bipolar intramyocardial electrogram from an implanted telemetric pacemaker for the diagnosis of cardiac allograft rejection.
Bonnefoy E; Ninet J; Robin J; Leroux F; Boissonat P; Brule P; Champsaur G
Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):2052-6. PubMed ID: 7845817
[TBL] [Abstract][Full Text] [Related]
18. Non-invasive graft monitoring after heart transplantation: rationale to reduce the number of endomyocardial biopsies.
Grasser B; Iberer F; Schaffellner S; Kniepeiss D; Schreier G; Kastner P; Tscheliessnigg KH
Transpl Int; 2000; 13 Suppl 1():S225-7. PubMed ID: 11112000
[TBL] [Abstract][Full Text] [Related]
19. Clinical heart transplantation without routine endomyocardial biopsy.
Warnecke H; Müller J; Cohnert T; Hummel M; Spiegelsberger S; Siniawski HK; Lieback E; Hetzer R
J Heart Lung Transplant; 1992; 11(6):1093-102. PubMed ID: 1457433
[TBL] [Abstract][Full Text] [Related]
20. Noninvasive monitoring of cardiac allograft rejection by intramyocardial electrogram recordings.
Warnecke H; Schüler S; Goetze HJ; Matheis G; Süthoff U; Müller J; Tietze U; Hetzer R
Circulation; 1986 Nov; 74(5 Pt 2):III72-6. PubMed ID: 3533318
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]