130 related articles for article (PubMed ID: 9828061)
1. In vitro thrombogenicity testing of artificial organs.
Paul R; Marseille O; Hintze E; Huber L; Schima H; Reul H; Rau G
Int J Artif Organs; 1998 Sep; 21(9):548-52. PubMed ID: 9828061
[TBL] [Abstract][Full Text] [Related]
2. Thrombogenic evaluation of two mechanical heart valve prostheses using a new in-vitro test system.
Kim CH; Steinseifer U; Schmitz-Rode T
J Heart Valve Dis; 2009 Mar; 18(2):207-13. PubMed ID: 19455896
[TBL] [Abstract][Full Text] [Related]
3. In vitro thrombogenic evaluation of centrifugal pumps.
Tayama E; Ohtsubo S; Nakazawa T; Takami Y; Niimi Y; Makinouchi K; Glueck J; Nosé Y
Artif Organs; 1997 May; 21(5):418-20. PubMed ID: 9129776
[TBL] [Abstract][Full Text] [Related]
4. An in-vitro technique for assessment of thrombogenicity in mechanical prosthetic cardiac valves: evaluation with a range of valve types.
Martin AJ; Christy JR
J Heart Valve Dis; 2004 May; 13(3):509-20. PubMed ID: 15222300
[TBL] [Abstract][Full Text] [Related]
5. A low-volume tester for the thrombogenic potential of mechanical heart valve prostheses.
Linde T; Hamilton KF; Timms DL; Schmitz-Rode T; Steinseifer U
J Heart Valve Dis; 2011 Sep; 20(5):510-7. PubMed ID: 22066354
[TBL] [Abstract][Full Text] [Related]
6. Thrombosis of mitral valve bioprostheses in patients requiring circulatory assistance.
Hagley MT; Lopez-Candales A; Phillips KJ; Daily BB; Kouchoukos NT
Ann Thorac Surg; 1995 Dec; 60(6):1814-6. PubMed ID: 8787495
[TBL] [Abstract][Full Text] [Related]
7. Massive aortic thrombus in patient with mechanical prosthetic valve supported with left ventricular assist device.
Tanawuttiwat T; Zelinger AB; Trivedi DA; Tatooles AJ
J Cardiovasc Comput Tomogr; 2011; 5(1):66-7. PubMed ID: 21051308
[TBL] [Abstract][Full Text] [Related]
8. In vitro investigation of thrombogenesis in rotary blood pumps.
Schima H; Siegl H; Mohammad SF; Huber L; Müller MR; Losert U; Thoma H; Wolner E
Artif Organs; 1993 Jul; 17(7):605-8. PubMed ID: 8338434
[TBL] [Abstract][Full Text] [Related]
9. Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: in vitro evaluation.
Kosaka R; Maruyama O; Nishida M; Yada T; Saito S; Hirai S; Yamane T
Artif Organs; 2009 Oct; 33(10):798-804. PubMed ID: 19681836
[TBL] [Abstract][Full Text] [Related]
10. In vitro thrombogenesis study in the Gyro C1E3 for vibration assessment.
Nakazawa T; Tayama E; Takami Y; Glueck J; Nosé Y
Artif Organs; 1997 Jul; 21(7):714-9. PubMed ID: 9212945
[TBL] [Abstract][Full Text] [Related]
11. In-vitro localization of initial flow-induced thrombus formation in bileaflet mechanical heart valves.
Scharfschwerdt M; Thomschke M; Sievers HH
ASAIO J; 2009; 55(1):19-23. PubMed ID: 19092660
[TBL] [Abstract][Full Text] [Related]
12. Real-Time Observation of Thrombus Growth Process in an Impeller of a Hydrodynamically Levitated Centrifugal Blood Pump by Near-Infrared Hyperspectral Imaging.
Sakota D; Murashige T; Kosaka R; Fujiwara T; Nishida M; Maruyama O
Artif Organs; 2015 Aug; 39(8):714-9. PubMed ID: 26234451
[TBL] [Abstract][Full Text] [Related]
13. In vitro thrombogenicity testing of pulsatile mechanical circulatory support systems: Design and proof-of-concept.
Brockhaus MK; Behbahani MJ; Muris F; Jansen SV; Schmitz-Rode T; Steinseifer U; Clauser JC
Artif Organs; 2021 Dec; 45(12):1513-1521. PubMed ID: 34312890
[TBL] [Abstract][Full Text] [Related]
14. Medical device-induced thrombosis: what causes it and how can we prevent it?
Jaffer IH; Fredenburgh JC; Hirsh J; Weitz JI
J Thromb Haemost; 2015 Jun; 13 Suppl 1():S72-81. PubMed ID: 26149053
[TBL] [Abstract][Full Text] [Related]
15. Development and evaluation of a swine model to assess the preclinical safety of mechanical heart valves.
Grehan JF; Hilbert SL; Ferrans VJ; Droel JS; Salerno CT; Bianco RW
J Heart Valve Dis; 2000 Sep; 9(5):710-9; discussion 719-20. PubMed ID: 11041189
[TBL] [Abstract][Full Text] [Related]
16. Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near-infrared light.
Sakota D; Murashige T; Kosaka R; Nishida M; Maruyama O
Artif Organs; 2014 Sep; 38(9):733-40. PubMed ID: 25234757
[TBL] [Abstract][Full Text] [Related]
17. Simple in vitro testing method for antithrombogenic evaluation of centrifugal blood pumps.
Maruyama O; Tomari Y; Sugiyama D; Nishida M; Tsutsui T; Yamane T
ASAIO J; 2009; 55(4):314-22. PubMed ID: 19471159
[TBL] [Abstract][Full Text] [Related]
18. Comparison of fondaparinux, low molecular-weight heparin and unfractionated heparin in preventing thrombus formation on mechanical heart valves: results of an in-vitro study.
Schlitt A; Hamilton K; Maegdefessel L; Dahm M; Theis C; Eichler M; Brockmann O; Steinseifer U; Hauroeder B; Hitzler WE; Rupprecht HJ
J Heart Valve Dis; 2006 Nov; 15(6):809-14. PubMed ID: 17152789
[TBL] [Abstract][Full Text] [Related]
19. In vitro comparison of dabigatran, unfractionated heparin, and low-molecular-weight heparin in preventing thrombus formation on mechanical heart valves.
Maegdefessel L; Linde T; Krapiec F; Hamilton K; Steinseifer U; van Ryn J; Raaz U; Buerke M; Werdan K; Schlitt A
Thromb Res; 2010 Sep; 126(3):e196-200. PubMed ID: 20659761
[TBL] [Abstract][Full Text] [Related]
20. Development of a disposable magnetically levitated centrifugal blood pump (MedTech Dispo) intended for bridge-to-bridge applications--two-week in vivo evaluation.
Nagaoka E; Someya T; Kitao T; Kimura T; Ushiyama T; Hijikata W; Shinshi T; Arai H; Takatani S
Artif Organs; 2010 Sep; 34(9):778-83. PubMed ID: 20928936
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]