These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 9828286)

  • 1. Assessment of the total artificial heart (TAH) pulsatility: the coalition between pulsatility and ejection time in TAH in vitro study.
    Nakata Ki; Ohashi Y; Muller J; Gleuck J; Nose Y
    Ann Thorac Cardiovasc Surg; 1998 Oct; 4(5):275-9. PubMed ID: 9828286
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new method of providing pulsatile flow in a centrifugal pump: assessment of pulsatility using a mock circulatory system.
    Herreros J; Berjano EJ; Sales-Nebot L; Más P; Calvo I; Mastrobuoni S; Mercé S
    Artif Organs; 2008 Jun; 32(6):490-4. PubMed ID: 18422794
    [TBL] [Abstract][Full Text] [Related]  

  • 3. MagScrew total artificial heart in vivo performance above 200 beats per minute.
    Schenk S; Weber S; Luangphakdy V; Klatte RS; Flick CR; Chen JF; Kopcak MW; Ootaki Y; Kamohara K; Hirschman GB; Vitale NG; Chapman PA; Smith WA; Fukamachi K
    Ann Thorac Surg; 2005 Apr; 79(4):1378-83; discussion 1383. PubMed ID: 15797082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Estimation of the native cardiac output from a rotary blood pump flow: in vitro study.
    Nakata K; Ohashi Y; Tayama E; Ohtsuka G; Takami Y; Mueller J; Glueck J; Nosé Y
    Artif Organs; 1998 May; 22(5):411-3. PubMed ID: 9609350
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mock circulation loop to investigate hemolysis in a pulsatile total artificial heart.
    Gräf F; Finocchiaro T; Laumen M; Mager I; Steinseifer U
    Artif Organs; 2015 May; 39(5):416-22. PubMed ID: 25586541
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller.
    Kleinheyer M; Timms DL; Tansley GD; Nestler F; Greatrex NA; Frazier OH; Cohn WE
    Artif Organs; 2016 Sep; 40(9):824-33. PubMed ID: 27645393
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemolysis in an electromechanical driven pulsatile total artificial heart.
    Ohashi Y; de Andrade A; Nosé Y
    Artif Organs; 2003 Dec; 27(12):1089-93. PubMed ID: 14678422
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device.
    Travis AR; Giridharan GA; Pantalos GM; Dowling RD; Prabhu SD; Slaughter MS; Sobieski M; Undar A; Farrar DJ; Koenig SC
    J Thorac Cardiovasc Surg; 2007 Feb; 133(2):517-24. PubMed ID: 17258591
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro and in vivo heat dissipation of an electrohydraulic totally implantable artificial heart.
    Endo S; Masuzawa T; Tatsumi E; Taenaka Y; Nakatani T; Ohno T; Wakisaka Y; Nishimura T; Takewa Y; Nakamura M; Takiura K; Sohn YS; Takano H
    ASAIO J; 1997; 43(5):M592-7. PubMed ID: 9360114
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous flow total artificial heart: modeling and feedback control in a mock circulatory system.
    Khalil HA; Kerr DT; Franchek MA; Metcalfe RW; Benkowski RJ; Cohn WE; Tuzun E; Radovancevic B; Frazier OH; Kadipasaoglu KA
    ASAIO J; 2008; 54(3):249-55. PubMed ID: 18496274
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A nonpulsatile total artificial heart with 1/R control.
    Abe Y; Saito I; Isoyama T; Miura H; Shi W; Yamaguchi S; Inoue Y; Nakagawa H; Ono M; Kishi A; Ono T; Kouno A; Chinzei T; Imachi K
    J Artif Organs; 2008; 11(4):191-200. PubMed ID: 19184283
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro controllability of the MagScrew total artificial heart system.
    Weber S; Doi K; Massiello AL; Byerman BP; Takagaki M; Fukamachi K; Donahue A; Chapman P; Hirschman G; Vitale N; Smith WA
    ASAIO J; 2002; 48(6):606-11. PubMed ID: 12455770
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pressures generated within the chambers of the MagScrew TAH: an in vitro study.
    Flick CR; Weber S; Luangphakdy V; Klatte RS; Fukamachi K; Smith WA
    ASAIO J; 2008; 54(1):58-63. PubMed ID: 18204317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Adaptive full-ejection point detection for automatic control of the electrohydraulic total artificial heart.
    Kim HC; Khanwilkar PS; Long JW; Olsen DB
    ASAIO J; 1993; 39(4):899-903. PubMed ID: 8123924
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel impeller TAH using magnetic bearings for load reduction.
    Qian KX; Ru WM; Zeng P; Yuan HY
    J Med Eng Technol; 2002; 26(5):214-6. PubMed ID: 12487713
    [TBL] [Abstract][Full Text] [Related]  

  • 16. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.
    Pelletier B; Spiliopoulos S; Finocchiaro T; Graef F; Kuipers K; Laumen M; Guersoy D; Steinseifer U; Koerfer R; Tenderich G
    Eur J Cardiothorac Surg; 2015 Jan; 47(1):80-6. PubMed ID: 25234093
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantification of pulsatility as a function of vascular input impedance: an in vitro study.
    Kaebnick BW; Giridharan GA; Koenig SC
    ASAIO J; 2007; 53(2):115-21. PubMed ID: 17413547
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Resonant frequency control method for total artificial heart: in vitro study.
    Kosaka R; Sankai Y; Yamane T; Tsutsui T
    Artif Organs; 2008 Feb; 32(2):157-60. PubMed ID: 18269353
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of left ventricular function and drive pressures on the filling and ejection of a pulsatile pediatric ventricular assist device in an acute animal model.
    Lukic B; Zapanta CM; Khalapyan T; Connell J; Pae WE; Myers JL; Wilson RP; Undar A; Rosenberg G; Weiss WJ
    ASAIO J; 2007; 53(3):379-84. PubMed ID: 17515733
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Augmented destruction test with an electromechanical pulsatile total artificial heart.
    Ohashi Y; Andrade A; Müller J; Nosé Y
    Artif Organs; 1999 Sep; 23(9):884-7. PubMed ID: 10636823
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.