These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 9840040)

  • 1. Intravascular MR-monitored balloon angioplasty: an in vivo feasibility study.
    Yang X; Bolster BD; Kraitchman DL; Atalar E
    J Vasc Interv Radiol; 1998; 9(6):953-9. PubMed ID: 9840040
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits.
    Yang X; Atalar E
    Radiology; 2000 Nov; 217(2):501-6. PubMed ID: 11058652
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance-guided percutaneous angioplasty of femoral and popliteal artery stenoses using real-time imaging and intra-arterial contrast-enhanced magnetic resonance angiography.
    Paetzel C; Zorger N; Bachthaler M; Hamer OW; Stehr A; Feuerbach S; Lenhart M; Völk M; Herold T; Kasprzak P; Nitz WR
    Invest Radiol; 2005 May; 40(5):257-62. PubMed ID: 15829822
    [TBL] [Abstract][Full Text] [Related]  

  • 4. MR-guided balloon angioplasty: in vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions.
    Bakker CJ; Smits HF; Bos C; van der Weide R; Zuiderveld KJ; van Vaals JJ; Hurtak WF; Viergever MA; Mali WP
    J Magn Reson Imaging; 1998; 8(1):245-50. PubMed ID: 9500288
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Feasibility of MR-guided angioplasty of femoral artery stenoses using real-time imaging and intraarterial contrast-enhanced MR angiography.
    Paetzel C; Zorger N; Bachthaler M; Völk M; Seitz J; Herold T; Feuerbach S; Lenhart M; Nitz WR
    Rofo; 2004 Sep; 176(9):1232-6. PubMed ID: 15346256
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endovascular treatment of experimental canine aneurysms: feasibility with MR imaging guidance.
    Strother CM; Unal O; Frayne R; Turk A; Omary R; Korosec FR; Mistretta CA
    Radiology; 2000 May; 215(2):516-9. PubMed ID: 10796934
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MR-guided balloon angioplasty of stenosed aorta: in vivo evaluation using near-standard instruments and a passive tracking technique.
    Godart F; Beregi JP; Nicol L; Occelli B; Vincentelli A; Daanen V; Rey C; Rousseau J
    J Magn Reson Imaging; 2000 Oct; 12(4):639-44. PubMed ID: 11042648
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monitoring of gadolinium-BOPTA uptake into the vessel wall during magnetic resonance (MR)-guided angioplasty of the peripheral arteries with a paclitaxel/gadolinium-BOPTA-coated balloon: an experimental study at 3 Tesla.
    Neizel M; Ruebben A; Weiss N; Günther RW; Kelm M; Krombach GA
    Rofo; 2014 Apr; 186(4):388-93. PubMed ID: 24142436
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Visualization of MR-compatible catheters by electrically induced local field inhomogeneities: evaluation in vivo.
    Adam G; Glowinski A; Neuerburg J; Bücker A; van Vaals JJ; Günther RW
    J Magn Reson Imaging; 1998; 8(1):209-13. PubMed ID: 9500282
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Magnetic resonance-guided angioplasty with delivery of contrast-media doped solutions to the vessel wall: an experimental study in swine.
    Krombach GA; Wehner M; Perez-Bouza A; Kaimann L; Kinzel S; Plum T; Schibur D; Friebe M; Günther RW; Hohl C
    Invest Radiol; 2008 Jul; 43(7):530-7. PubMed ID: 18580336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: assessment and validation in a large animal model.
    Schalla S; Saeed M; Higgins CB; Weber O; Martin A; Moore P
    J Magn Reson Imaging; 2005 Mar; 21(3):204-11. PubMed ID: 15723375
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR-Guided PTA in experimental bilateral rabbit renal artery stenosis and MR angiography follow-up versus histomorphometry.
    Le Blanche AF; Rossert J; Wassef M; Lévy B; Bigot JM; Boudghene F
    Cardiovasc Intervent Radiol; 2000; 23(5):368-74. PubMed ID: 11060367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures.
    Unal O; Korosec FR; Frayne R; Strother CM; Mistretta CA
    Magn Reson Med; 1998 Sep; 40(3):356-62. PubMed ID: 9727937
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcutaneous ultrasonography can be used to guide and monitor balloon angioplasty.
    Cluley SR; Brener BJ; Hollier L; Schoenfeld R; Novick A; Vilkomerson D; Ferrara-Ryan M; Parsonnet V
    J Vasc Surg; 1993 Jan; 17(1):23-30; discussion 30-1. PubMed ID: 8421339
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic pitfalls in postinterventional intraarterial magnetic resonance angiography after recanalization of femoropopliteal arterial occlusions.
    Huegli RW; Aschwanden M; Kos S; Rasmus M; Jaeger K; Jacob AL; Bilecen D
    Acta Radiol; 2008 Dec; 49(10):1129-36. PubMed ID: 19031180
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MR-guided percutaneous angioplasty: assessment of tracking safety, catheter handling and functionality.
    Wildermuth S; Dumoulin CL; Pfammatter T; Maier SE; Hofmann E; Debatin JF
    Cardiovasc Intervent Radiol; 1998; 21(5):404-10. PubMed ID: 9853147
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Chimney stent technique for treatment of severe abdominal aortic atherosclerotic stenosis.
    Ritter JC; Ghosh J; Butterfield JS; McCollum CN; Ashleigh R
    J Vasc Interv Radiol; 2011 Mar; 22(3):391-4. PubMed ID: 21277799
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intravascular MR tracking catheter: preliminary experimental evaluation.
    Leung DA; Debatin JF; Wildermuth S; McKinnon GC; Holtz D; Dumoulin CL; Darrow RD; Hofmann E; von Schulthess GK
    AJR Am J Roentgenol; 1995 May; 164(5):1265-70. PubMed ID: 7717244
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Aortic and lower-extremity arterial disease: evaluation with MR angiography versus conventional angiography.
    Quinn SF; Sheley RC; Semonsen KG; Leonardo VJ; Kojima K; Szumowski J
    Radiology; 1998 Mar; 206(3):693-701. PubMed ID: 9494487
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.
    Kivelitz D; Wagner S; Schnorr J; Wetzler R; Busch M; Melzer A; Taupitz M; Hamm B
    Invest Radiol; 2003 Mar; 38(3):147-52. PubMed ID: 12595794
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.