22. [Extraneous signal modification of cardiac pacemakers by high frequency fields]. Hansen V Biomed Tech (Berl); 1990; 35 Suppl 3():292-3. PubMed ID: 2078741 [No Abstract] [Full Text] [Related]
25. [Pacemaker dysfunction during use of a mobile telephone]. Vlasínová J; Novotný T Vnitr Lek; 2000 Feb; 46(2):119-21. PubMed ID: 11048537 [TBL] [Abstract][Full Text] [Related]
26. Do induction cooktops interfere with cardiac pacemakers? Irnich W; Bernstein AD Europace; 2006 May; 8(5):377-84. PubMed ID: 16635999 [TBL] [Abstract][Full Text] [Related]
27. Are microwave ovens, cell phones, and other such devices dangerous to people with pacemakers? Johns Hopkins Med Lett Health After 50; 2000 May; 12(3):8. PubMed ID: 10798288 [No Abstract] [Full Text] [Related]
29. Study of Pacemaker and Implantable CardiovErter Defibrillator Triggering by Electronic Article Surveillance devices (SPICED TEAS). Becker G; Johnson D Pacing Clin Electrophysiol; 1999 Mar; 22(3):542. PubMed ID: 10192871 [No Abstract] [Full Text] [Related]
30. SPICED TEAS manuscript. Study of Pacemaker and Implantable CardiovErter Defibrillator Triggering by Electronic Article Surveillance devices. McIvor ME; Sheppard RC Pacing Clin Electrophysiol; 1999 Mar; 22(3):540-1. PubMed ID: 10192870 [No Abstract] [Full Text] [Related]
31. Four types of interaction between pacemakers and EAS systems. Kunisada K Pacing Clin Electrophysiol; 1999 Feb; 22(2):402-3. PubMed ID: 10087565 [No Abstract] [Full Text] [Related]
32. Effects of electromagnetic interference on implanted cardiac devices and their management. Yerra L; Reddy PC Cardiol Rev; 2007; 15(6):304-9. PubMed ID: 18090066 [TBL] [Abstract][Full Text] [Related]
33. [Use of high-frequency current in endoscopy in patients with cardiac pacemakers]. Jung W; Neubrand M; Lüderitz B Z Gastroenterol; 1994 Aug; 32(8):479-82. PubMed ID: 7975794 [No Abstract] [Full Text] [Related]
34. [Disruption of cardiac pacemaker function by magnetic buttons on clothing]. Kober G; Kloster T Dtsch Med Wochenschr; 2000 Feb; 125(7):186. PubMed ID: 10719393 [No Abstract] [Full Text] [Related]
35. [Effect of external electrical interference on pacemakers]. Frank R; Himbert C; Hidden-Lucet F; Petitot JC; Fontaine G Ann Cardiol Angeiol (Paris); 2000 Jul; 49(4):238-44. PubMed ID: 12555485 [TBL] [Abstract][Full Text] [Related]
36. [Is there any risk interaction between electromagnetic field generated by mobile phones and artificial pacemakers]. Derkacz A; Poreba R; Skoczyńska A; Andrzejak R Med Pr; 2001; 52(2):107-10. PubMed ID: 11761658 [TBL] [Abstract][Full Text] [Related]
37. Electromagnetic compatibility of electronic implants--review of the literature. Kainz W; Neubauer G; Alesch F; Schmid G; Jahn O Wien Klin Wochenschr; 2001 Dec; 113(23-24):903-14. PubMed ID: 11802505 [TBL] [Abstract][Full Text] [Related]
38. Power lines and implantable rhythm devices. Souques M Expert Rev Cardiovasc Ther; 2009 Mar; 7(3):222; author reply 223. PubMed ID: 19296756 [No Abstract] [Full Text] [Related]
39. [Behavior of 20 pacemakers as patients pass through 2 models of theft-detection doors]. Frank R Ann Cardiol Angeiol (Paris); 2000 Jun; 49(3):187-97. PubMed ID: 12555480 [TBL] [Abstract][Full Text] [Related]
40. [Signal modification of implanted cardiac pacemakers caused by physical therapy equipment]. Jacob C; Volkmann H; Ziegenhahn C; Uhlemann C Z Arztl Fortbild (Jena); 1990; 84(9):443-7. PubMed ID: 2378125 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]