BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 9843598)

  • 1. Production and systemic absorption of toxic byproducts of tissue combustion during laparoscopic cholecystectomy.
    Wu JS; Monk T; Luttmann DR; Meininger TA; Soper NJ
    J Gastrointest Surg; 1998; 2(5):399-405. PubMed ID: 9843598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Production and systemic absorption of toxic byproducts of tissue combustion during laparoscopic surgery.
    Wu JS; Luttmann DR; Meininger TA; Soper NJ
    Surg Endosc; 1997 Nov; 11(11):1075-9. PubMed ID: 9348377
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Perioperative changes in carbonylhemoglobin and methemoglobin during abdominal surgery: alteration in endogenous generation of carbon monoxide.
    Takeda R; Tanaka A; Maeda T; Yamaoka Y; Nakamura K; Sano K; Kataoka M; Nakamura Y; Morimoto T; Mukaihara S
    J Gastroenterol Hepatol; 2002 May; 17(5):535-41. PubMed ID: 12084025
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High levels of carbon monoxide are produced by electro-cautery of tissue during laparoscopic cholecystectomy.
    Beebe DS; Swica H; Carlson N; Palahniuk RJ; Goodale RL
    Anesth Analg; 1993 Aug; 77(2):338-41. PubMed ID: 8346835
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Carboxyhemoglobin and methemoglobin in asthma.
    Naples R; Laskowski D; McCarthy K; Mattox E; Comhair SA; Erzurum SC
    Lung; 2015 Apr; 193(2):183-7. PubMed ID: 25680415
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Closed-system anaesthesia for laparoscopic surgery: is there a risk for carbon monoxide intoxication?
    Soro M; García-Pérez ML; Ferrandis R; Aguilar G; Belda EJ
    Eur J Anaesthesiol; 2004 Jun; 21(6):483-8. PubMed ID: 15248629
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner.
    Bickler MP; Rhodes LJ
    PLoS One; 2018; 13(3):e0193891. PubMed ID: 29513738
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transperitoneal absorption of thermocautery-induced carbon monoxide formation during laparoscopic cholecystectomy.
    Esper E; Russell TE; Coy B; Duke BE; Max MH; Coil JA
    Surg Laparosc Endosc; 1994 Oct; 4(5):333-5. PubMed ID: 8000628
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Carboxyhemoglobinemia due to peritoneal smoke absorption from laser tissue combustion at laparoscopy.
    Ott DE
    J Clin Laser Med Surg; 1998 Dec; 16(6):309-15. PubMed ID: 10204436
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Effects of carbon monoxide produced during laparoscopic surgery].
    Tamura T; Fukuda S; Iida Y; Morimoto Y; Shimizu K; Miyauchi Y
    Masui; 1995 Dec; 44(12):1722-4. PubMed ID: 8583676
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of carboxyhemoglobin, hydrogen cyanide and methemoglobin in fire victims: a novel approach.
    Ferrari LA; Giannuzzi L
    Forensic Sci Int; 2015 Nov; 256():46-52. PubMed ID: 26426954
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The measurement of carboxyhemoglobin and methemoglobin using a non-invasive pulse CO-oximeter.
    Zaouter C; Zavorsky GS
    Respir Physiol Neurobiol; 2012 Jul; 182(2-3):88-92. PubMed ID: 22609179
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Carboxyhemoglobin and methemoglobin levels as prognostic markers in acute pulmonary embolism.
    Kakavas S; Papanikolaou A; Ballis E; Tatsis N; Goga C; Tatsis G
    Am J Emerg Med; 2015 Apr; 33(4):563-8. PubMed ID: 25769799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-invasive measurements of carboxyhemoglobin and methemoglobin in children with sickle cell disease.
    Caboot JB; Jawad AF; McDonough JM; Bowdre CY; Arens R; Marcus CL; Mason TB; Smith-Whitley K; Ohene-Frempong K; Allen JL
    Pediatr Pulmonol; 2012 Aug; 47(8):808-15. PubMed ID: 22328189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemodynamic Implications of Carbon Monoxide (CO) and Nitrogen Oxide (NO) during Living Donor Liver Transplantation.
    Lim H; Lee SK; Kim G
    Tohoku J Exp Med; 2017 Nov; 243(3):179-186. PubMed ID: 29176268
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The effect of hyperbilirubinemia on the measurement of oxygenated hemoglobin (O2Hb), carboxyhemoglobin (COHb) and methemoglobin (MetHb) using multiwavelength oximeters in mixed venous blood].
    Lampert R; Brandt L
    Anaesthesist; 1993 Oct; 42(10):702-9. PubMed ID: 8250204
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Evolution of the carboxyhemoglobinemia and methemoglobinemia during endoscopic resection: An observational study].
    Bairy L; Hardy G; Di Gregorio M; Bihin B
    Prog Urol; 2017 Feb; 27(2):98-102. PubMed ID: 28117232
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retrospective evaluation of carboxyhemoglobin and methemoglobin levels in dogs and cats with respiratory disease.
    Wolf JM; Hess RS; Hering CT; Silverstein DC
    J Vet Emerg Crit Care (San Antonio); 2022 Sep; 32(5):637-644. PubMed ID: 35442550
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Influence of Smoking on the Variations in Carboxyhemoglobin and Methemoglobin During Urologic Surgery.
    Gavrilovska-Brzanov A; Shosholcheva M; Kuzmanovska B; Kartalov A; Mojsova-Mijovska M; Jovanovski-Srceva M; Taleska G; Brzanov N; Simeonov R; Miceska MS
    Med Arch; 2017 Jun; 71(3):178-182. PubMed ID: 28974829
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The usefulness of carboxyhemoglobin, methemoglobin and blood lactate concentration in evaluating the health condition of Kraków inhabitants exposed to primary pollutants.
    Groszek B; Szpak D; Nitecki J; Brodkiewicz A
    Przegl Lek; 1996; 53(4):338-41. PubMed ID: 8711187
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.