133 related articles for article (PubMed ID: 9846069)
1. Validation of a high voltage leak detector for use with pharmaceutical blow-fill-seal containers--a practical approach.
Möll F; Doyle DL; Haerer M; Morton Guazzo D
PDA J Pharm Sci Technol; 1998; 52(5):215-27. PubMed ID: 9846069
[TBL] [Abstract][Full Text] [Related]
2. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 1. Method development and validation.
Damgaard R; Rasmussen M; Buus P; Mulhall B; Guazzo DM
PDA J Pharm Sci Technol; 2013; 67(6):634-51. PubMed ID: 24265304
[TBL] [Abstract][Full Text] [Related]
3. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.
Simonetti A; Amari F
PDA J Pharm Sci Technol; 2015; 69(1):108-22. PubMed ID: 25691719
[TBL] [Abstract][Full Text] [Related]
4. High-Voltage Leak Detection of a Parenteral Proteinaceous Solution Product Packaged in Form-Fill-Seal Plastic Laminate Bags. Part 3. Chemical Stability and Visual Appearance of a Protein-Based Aqueous Solution for Injection as a Function of HVLD Exposure.
Rasmussen M; Damgaard R; Buus P; Guazzo DM
PDA J Pharm Sci Technol; 2013; 67(6):664-9. PubMed ID: 24265306
[TBL] [Abstract][Full Text] [Related]
5. High-voltage leak detection of a parenteral proteinaceous solution product packaged in form-fill-seal plastic laminate bags. Part 2. Method performance as a function of heat seal defects, product-package refrigeration, and package plastic laminate lot.
Rasmussen M; Damgaard R; Buus P; Mulhall B; Guazzo DM
PDA J Pharm Sci Technol; 2013; 67(6):652-63. PubMed ID: 24265305
[TBL] [Abstract][Full Text] [Related]
6. Balancing Container Closure Integrity and Aesthetics for a Robust Aseptic or Sterile Vial Packaging System.
Oni Y; Song X; Schrader M; Kulshrestha A; Franck J; Asselta R; Flores-Crespo C; Mantri RV
PDA J Pharm Sci Technol; 2019; 73(6):572-587. PubMed ID: 31101708
[TBL] [Abstract][Full Text] [Related]
7. Pharmaceutical container/closure integrity. III: Validation of the helium leak rate method for rigid pharmaceutical containers.
Kirsch LE; Nguyen L; Gerth R
PDA J Pharm Sci Technol; 1997; 51(5):203-7. PubMed ID: 9357306
[TBL] [Abstract][Full Text] [Related]
8. Vacuum decay container closure integrity leak test method development and validation for a lyophilized product-package system.
Patel J; Mulhall B; Wolf H; Klohr S; Guazzo DM
PDA J Pharm Sci Technol; 2011; 65(5):486-505. PubMed ID: 22293838
[TBL] [Abstract][Full Text] [Related]
9. Ozone Generation during High-Voltage Leak Detection: Fiction or Reality?
Becker S; Reimers K; Bickert V; Becker M
PDA J Pharm Sci Technol; 2018; 72(4):404-410. PubMed ID: 29444991
[TBL] [Abstract][Full Text] [Related]
10. Method Development for Container Closure Integrity Evaluation via Headspace Gas Ingress by Using Frequency Modulation Spectroscopy.
Victor KG; Levac L; Timmins M; Veale J
PDA J Pharm Sci Technol; 2017; 71(6):429-453. PubMed ID: 28733333
[TBL] [Abstract][Full Text] [Related]
11. Comparing Physical Container Closure Integrity Test Methods and Artificial Leak Methodologies.
Peláez SS; Mahler HC; Herdlitschka C; Wertli T; Kahl M; Koulov A; Matter A; Singh SK; Widmer M; Germershaus O; Mathaes R
PDA J Pharm Sci Technol; 2019; 73(3):220-234. PubMed ID: 30651337
[TBL] [Abstract][Full Text] [Related]
12. Pharmaceutical container/closure integrity. IV: Development of an indirect correlation between vacuum decay leak measurement and microbial ingress.
Nguyen LT; Muangsiri W; Schiere R; Guazzo DK; Kirsch LE
PDA J Pharm Sci Technol; 1999; 53(4):211-6. PubMed ID: 10754714
[TBL] [Abstract][Full Text] [Related]
13. Vacuum decay container/closure integrity testing technology. Part 2. Comparison to dye ingress tests.
Wolf H; Stauffer T; Chen SC; Lee Y; Forster R; Ludzinski M; Kamat M; Mulhall B; Guazzo DM
PDA J Pharm Sci Technol; 2009; 63(5):489-98. PubMed ID: 20158053
[TBL] [Abstract][Full Text] [Related]
14. Container Closure Integrity Testing-Practical Aspects and Approaches in the Pharmaceutical Industry.
Brown H; Mahler HC; Mellman J; Nieto A; Wagner D; Schaar M; Mathaes R; Kossinna J; Schmitting F; Dreher S; Roehl H; Hemminger M; Wuchner K
PDA J Pharm Sci Technol; 2017; 71(2):147-162. PubMed ID: 27789803
[TBL] [Abstract][Full Text] [Related]
15. Quantifying the Vial Capping Process: Residual Seal Force and Container Closure Integrity.
Ovadia R; Streubel A; Webb-Vargas Y; Ulland L; Luemkemann J; Rauch K; Eder J; Lam P; Tegoulia V; Maa YF
PDA J Pharm Sci Technol; 2019; 73(1):2-15. PubMed ID: 29954924
[TBL] [Abstract][Full Text] [Related]
16. The Application of Noninvasive Headspace Analysis to Media Fill Inspection.
Duncan D; Cundell T; Levac L; Veale J; Kuiper S; Rao R
PDA J Pharm Sci Technol; 2016; 70(3):230-47. PubMed ID: 26865678
[TBL] [Abstract][Full Text] [Related]
17. Considerations for design and use of container challenge sets for qualification and validation of visible particulate inspection.
Melchore JA; Berdovich D
PDA J Pharm Sci Technol; 2012; 66(3):273-84. PubMed ID: 22634593
[TBL] [Abstract][Full Text] [Related]
18. Environmental microbial challenges to an aseptic Blow-Fill-Seal process--a practical study.
Jones DJ; Topping P; Sharp J
PDA J Pharm Sci Technol; 1995; 49(5):226-34. PubMed ID: 7489196
[TBL] [Abstract][Full Text] [Related]
19. Feasibility of Using Fluorescence Spectrophotometry to Develop a Sensitive Dye Immersion Method for Container Closure Integrity Testing of Prefilled Syringes.
Lu X; Lloyd DK; Klohr SE
PDA J Pharm Sci Technol; 2016; 70(1):39-50. PubMed ID: 26889055
[TBL] [Abstract][Full Text] [Related]
20. Investigation of pulsed light for terminal sterilization of WFI filled blow/fill/seal polyethylene containers.
Dunn J; Burgess D; Leo F
PDA J Pharm Sci Technol; 1997; 51(3):111-5. PubMed ID: 9203823
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]