These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 9847604)

  • 1. [MR-cholangiopancreatography using three-dimensional Fourier transfer fast asymmetric spin-echo method (3DFT-FASE)--clinical evaluation].
    Yamakawa K; Satake H; Naganawa S; Fukatsu H; Ishigaki T
    Nihon Rinsho; 1998 Nov; 56(11):2825-9. PubMed ID: 9847604
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical evaluation of three-dimensional MR-cholangiopancreatography using three-dimensional Fourier transform fast asymmetric spin echo method (3DFT-FASE): usefulness of observation by multi-planar reconstruction.
    Yamakawa K; Naganawa S; Maruyama K; Kato T; Fukatsu H; Ishigaki T
    Radiat Med; 1999; 17(1):15-9. PubMed ID: 10378647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [MR cholangiopancreatography with single-shot fast-spin-echo sequences].
    Shiratori Y; Kanematsu M; Hoshi H; Moriwaki H
    Nihon Rinsho; 1998 Nov; 56(11):2842-8. PubMed ID: 9847607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Optimization of pulse sequences for MR cholangiopancreatography with FASE].
    Akiyama H; Ohgi K; Kimura S; Higashi M
    Nihon Rinsho; 1998 Nov; 56(11):2813-6. PubMed ID: 9847602
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Maximum intensity projection (MIP) and multiplanar reformation (MPR) for post-processing cholangiopancreatographic data set--clinical application and pitfalls].
    Isogai S; Takehara Y; Isoda H; Kaneko M
    Nihon Rinsho; 1998 Nov; 56(11):2760-7. PubMed ID: 9847595
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Basic principles and historical consideration of MR cholangiopancreatography].
    Ohgi K; Furukawa T; Akiyama H; Kimura S; Uehara K; Murata K
    Nihon Rinsho; 1998 Nov; 56(11):2755-9. PubMed ID: 9847594
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Efficacy of respiratory-triggered fast spin-echo 3 dimensional-MR cholangiopancreatography on middle magnetic field MR imaging].
    Isomoto I; Koshiishi T; Uetani M; Hayashi K
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Mar; 57(4):170-5. PubMed ID: 9125872
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [PSIF/CE-FAST (fast gradient echo) and TSE (turbo spin echo)].
    Miyazaki T; Yamashita Y; Takahashi M
    Nihon Rinsho; 1998 Nov; 56(11):2773-7. PubMed ID: 9847597
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Clinical evaluation of MRCP].
    Sai J; Ariyama J; Suyama M; Kubokawa Y; Yamanaka K; Irimoto M; Hongo K
    Nihon Rinsho; 1998 Nov; 56(11):2768-72. PubMed ID: 9847596
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MR cholangiopancreatography: potential clinical applications.
    Reinbold C; Bret PM; Guibaud L; Barkun AN; Genin G; Atri M
    Radiographics; 1996 Mar; 16(2):309-20. PubMed ID: 8966289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Breath-hold MR cholangiopancreatography with 2D and 3D-FASE sequence at 0.5 tesla: evaluation based on measurements of signal intensity ratio and contrast-to-noise ratio].
    Ichikawa T; Hanaoka H; Nitatori T; Hachiya J; Araki T
    Nihon Rinsho; 1998 Nov; 56(11):2817-24. PubMed ID: 9847603
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR cholangiopancreatography: comparison of 2D single-shot fast spin-echo and 3D fast spin-echo sequences.
    Cova M; Stacul F; Cester G; Ukmar M; Pozzi Mucelli R
    Radiol Med; 2003 Sep; 106(3):178-90. PubMed ID: 14612839
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Efficacy of multidirection MRCP].
    Koike S; Honjo K; Yasui M; Matsunaga N
    Nihon Rinsho; 1998 Nov; 56(11):2808-12. PubMed ID: 10049032
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The utilities and outlooks of MR cholangiography (MRCP) as a non contrast and noninvasive technique].
    Hachiya J; Haradome H
    Nihon Rinsho; 1998 Nov; 56(11):2747-54. PubMed ID: 9847593
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Usefulness of T2-weighted images using single shot fast spin echo (SSFSE) pulse sequence for the evaluation of pancreatobiliary diseases: comparison with MRCP using SSFSE].
    Kadoya M; Gabata T; Matsui O; Kawamori Y; Takashima T; Matsuura Y; Kurata Y; Kawahara K
    Nihon Rinsho; 1998 Nov; 56(11):2836-41. PubMed ID: 9847606
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MR cholangiopancreatography (MRCP).
    Vrachliotis TG; Shirkhoda A; Bis KG; Shetty AN; Konez O; Ference JJ; Madrazo BL
    Crit Rev Diagn Imaging; 1997 Aug; 38(4):295-323. PubMed ID: 9376087
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Single shot MRI cholangiopancreatography (MRCP) with a "fast acquisition spin echo" sequence (FASE). Replacement of ERCP?].
    Schulte B; Beyer D; Wedekind G; Meuser W
    Aktuelle Radiol; 1998 Jan; 8(1):18-24. PubMed ID: 9538925
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Demonstration of normal bile duct and pancreatic duct with MR cholangiopancreatography].
    Toda J; Ueno E; Takada Y; Okawa T
    Nihon Rinsho; 1998 Nov; 56(11):2830-5. PubMed ID: 9847605
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Clinical usefulness of fat suppression technique for MR cholangiopancreatography (MRCP)].
    Dohke M; Watanabe Y; Amoh Y; Ishimori T; Okumura A; Oda K; Hayashi T; Hiyama A; Dodo Y
    Nihon Rinsho; 1998 Nov; 56(11):2870-3. PubMed ID: 9847612
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Free breathing magnetic resonance cholangiopancreatography (MRCP) at end expiration: a new technique to expand clinical application.
    Chen JH; Chai JW; Chu WC; Chang JM; Shen WC; Lee SK
    Hepatogastroenterology; 2002; 49(45):593-6. PubMed ID: 12063947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.