These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 9855207)

  • 1. Pathologic supracondylar fracture due to osteolytic pseudotumor of knee following cementless total knee replacement.
    Benevenia J; Lee FY; Buechel F; Parsons JR
    J Biomed Mater Res; 1998; 43(4):473-7. PubMed ID: 9855207
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thigh mass associated with polyethylene wear-induced osteolysis after cementless total hip arthroplasty.
    Park YS; Lim SJ; Kim JH; Wala A
    Arch Orthop Trauma Surg; 2010 Sep; 130(9):1097-101. PubMed ID: 19816700
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Osteolytic lesion of the tibial diaphysis after cementless TKA.
    Vernon BA; Bollinger AJ; Garvin KL; McGarry SV
    Orthopedics; 2011 Mar; 34(3):224. PubMed ID: 21410114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles.
    Willert HG; Bertram H; Buchhorn GH
    Clin Orthop Relat Res; 1990 Sep; (258):95-107. PubMed ID: 2203577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty.
    Huang CH; Yang CY; Cheng CK
    J Arthroplasty; 1999 Apr; 14(3):375-9. PubMed ID: 10220194
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Osteolytic pseudotumor after cemented total knee arthroplasty.
    Kinney MC; Kamath AF
    Am J Orthop (Belle Mead NJ); 2013 Nov; 42(11):512-4. PubMed ID: 24340321
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An osteolytic lesion associated with polyethylene wear debris adjacent to a stable total knee prosthesis.
    Kane KR; DeHeer DH; Beebe JD; Bereza R
    Orthop Rev; 1994 Apr; 23(4):332-7. PubMed ID: 8008443
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Wear debris associated with a large lateral femoral condyle cyst following an Oxford medial unicompartmental knee replacement.
    Hart WJ; Jones RS
    Knee; 2004 Oct; 11(5):409-12. PubMed ID: 15351419
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aggressive granulomatosis after cementless total hip arthroplasty as a result of inflammatory reaction to metal debris: case report.
    Sebecić B; Japjec M; Dojcinović B; Zgaljardić I; Staresinić M
    Acta Clin Croat; 2013 Dec; 52(4):492-6. PubMed ID: 24697001
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biological reactions to wear debris in total joint replacement.
    Ingham E; Fisher J
    Proc Inst Mech Eng H; 2000; 214(1):21-37. PubMed ID: 10718048
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [A rare case of extensive bilateral polyethylene granuloma after knee replacement].
    Vavrík P; Popelka S; Vírava J
    Acta Chir Orthop Traumatol Cech; 2001; 68(5):320-3. PubMed ID: 11759476
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tibial insert undersurface as a contributing source of polyethylene wear debris.
    Wasielewski RC; Parks N; Williams I; Surprenant H; Collier JP; Engh G
    Clin Orthop Relat Res; 1997 Dec; (345):53-9. PubMed ID: 9418621
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. A cause of late failure.
    Cooper RA; McAllister CM; Borden LS; Bauer TW
    J Arthroplasty; 1992 Sep; 7(3):285-90. PubMed ID: 1402944
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metallosis following knee arthroplasty: a histological and immunohistochemical study.
    Schiavone Panni A; Vasso M; Cerciello S; Maccauro G
    Int J Immunopathol Pharmacol; 2011; 24(3):711-9. PubMed ID: 21978703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Pathologic fracture of the distal femur in total knee arthroplasty. Polyethylene-wear-induced osteolysis? A case report].
    Napp M; Frank M; Witt M
    Orthopade; 2009 Oct; 38(10):970, 972-3. PubMed ID: 19639299
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement.
    Urban RM; Jacobs JJ; Tomlinson MJ; Gavrilovic J; Black J; Peoc'h M
    J Bone Joint Surg Am; 2000 Apr; 82(4):457-76. PubMed ID: 10761937
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Osteolysis of the distal femur after total knee arthroplasty.
    Cadambi A; Engh GA; Dwyer KA; Vinh TN
    J Arthroplasty; 1994 Dec; 9(6):579-94. PubMed ID: 7699370
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is There a Benefit to Highly Crosslinked Polyethylene in Posterior-stabilized Total Knee Arthroplasty? A Randomized Trial.
    Lachiewicz PF; Soileau ES
    Clin Orthop Relat Res; 2016 Jan; 474(1):88-95. PubMed ID: 25762016
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Medium-term osteolysis with the Wallaby I® deep-dished total knee prosthesis.
    Marion B; Huten D; Boyer P; Jeanrot C; Massin P
    Orthop Traumatol Surg Res; 2014 Jun; 100(4):403-8. PubMed ID: 24794498
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
    Krbec M; Motycka J; Lunácek L; Dousa P
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.