233 related articles for article (PubMed ID: 9857588)
1. Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis.
Stegaroiu R; Kusakari H; Nishiyama S; Miyakawa O
Int J Oral Maxillofac Implants; 1998; 13(6):781-90. PubMed ID: 9857588
[TBL] [Abstract][Full Text] [Related]
2. Stress distribution on the metal framework of the implant-supported fixed prosthesis using different veneering materials.
Ciftçi Y; Canay S
Int J Prosthodont; 2001; 14(5):406-11. PubMed ID: 12066633
[TBL] [Abstract][Full Text] [Related]
3. The effect of veneering materials on stress distribution in implant-supported fixed prosthetic restorations.
Ciftçi Y; Canay S
Int J Oral Maxillofac Implants; 2000; 15(4):571-82. PubMed ID: 10960992
[TBL] [Abstract][Full Text] [Related]
4. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis.
Wang TM; Leu LJ; Wang J; Lin LD
Int J Oral Maxillofac Implants; 2002; 17(2):231-7. PubMed ID: 11958406
[TBL] [Abstract][Full Text] [Related]
5. Influence of superstructure materials on strain around an implant under 2 loading conditions: a technical investigation.
Stegaroiu R; Khraisat A; Nomura S; Miyakawa O
Int J Oral Maxillofac Implants; 2004; 19(5):735-42. PubMed ID: 15508991
[TBL] [Abstract][Full Text] [Related]
6. Finite element analysis study of the effect of superstructure material on stress distribution in an implant-supported fixed prosthesis.
Sertgöz A
Int J Prosthodont; 1997; 10(1):19-27. PubMed ID: 9484066
[TBL] [Abstract][Full Text] [Related]
7. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
[TBL] [Abstract][Full Text] [Related]
8. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
Sütpideler M; Eckert SE; Zobitz M; An KN
Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
[TBL] [Abstract][Full Text] [Related]
9. Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis.
Chun HJ; Shin HS; Han CH; Lee SH
Int J Oral Maxillofac Implants; 2006; 21(2):195-202. PubMed ID: 16634489
[TBL] [Abstract][Full Text] [Related]
10. Finite element analysis studies of a metal-ceramic crown on a first premolar tooth.
Proos KA; Swain MV; Ironside J; Steven GP
Int J Prosthodont; 2002; 15(6):521-7. PubMed ID: 12475155
[TBL] [Abstract][Full Text] [Related]
11. Two dental implants designed for immediate loading: a finite element analysis.
Pierrisnard L; Hure G; Barquins M; Chappard D
Int J Oral Maxillofac Implants; 2002; 17(3):353-62. PubMed ID: 12074450
[TBL] [Abstract][Full Text] [Related]
12. Examination of the implant-abutment interface after fatigue testing.
Cibirka RM; Nelson SK; Lang BR; Rueggeberg FA
J Prosthet Dent; 2001 Mar; 85(3):268-75. PubMed ID: 11264934
[TBL] [Abstract][Full Text] [Related]
13. Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis.
Cehreli MC; Akça K; Iplikçioğlu H
Clin Oral Implants Res; 2004 Aug; 15(4):481-9. PubMed ID: 15248884
[TBL] [Abstract][Full Text] [Related]
14. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns.
Kim Y; Yamashita J; Shotwell JL; Chong KH; Wang HL
J Prosthet Dent; 2006 Jun; 95(6):450-5. PubMed ID: 16765158
[TBL] [Abstract][Full Text] [Related]
15. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.
Uysal H; Kurtoglu C; Gurbuz R; Tutuncu N
J Prosthet Dent; 2005 Mar; 93(3):235-44. PubMed ID: 15775924
[TBL] [Abstract][Full Text] [Related]
16. An investigation of heat transfer to the implant-bone interface related to exothermic heat generation during setting of autopolymerizing acrylic resins applied directly to an implant abutment.
Ormianer Z; Laufer BZ; Nissan J; Gross M
Int J Oral Maxillofac Implants; 2000; 15(6):837-42. PubMed ID: 11151583
[TBL] [Abstract][Full Text] [Related]
17. Finite element stress analysis of the influence of staggered versus straight placement of dental implants.
Akça K; Iplikçioğlu H
Int J Oral Maxillofac Implants; 2001; 16(5):722-30. PubMed ID: 11669255
[TBL] [Abstract][Full Text] [Related]
18. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.
Sevimay M; Turhan F; Kiliçarslan MA; Eskitascioglu G
J Prosthet Dent; 2005 Mar; 93(3):227-34. PubMed ID: 15775923
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional finite element stress analysis of a cuneiform-geometry implant.
Cruz M; Wassall T; Toledo EM; Barra LP; Lemonge AC
Int J Oral Maxillofac Implants; 2003; 18(5):675-84. PubMed ID: 14579955
[TBL] [Abstract][Full Text] [Related]
20. Implant-supported fixed partial prostheses: a retrospective study.
Johansson LA; Ekfeldt A
Int J Prosthodont; 2003; 16(2):172-6. PubMed ID: 12737250
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]