121 related articles for article (PubMed ID: 9858973)
1. Effect of baffles and a louvered bypass on the airflow and the convective patterns of contaminant inside a fume hood.
Hu P; Ingham DB; Wen X
Am Ind Hyg Assoc J; 1998 May; 59(5):303-12. PubMed ID: 9858973
[TBL] [Abstract][Full Text] [Related]
2. Numerical simulation of airflow around a variable volume/constant face velocity fume cupboard.
Lan NS; Viswanathan S
AIHAJ; 2001; 62(3):303-12. PubMed ID: 11434436
[TBL] [Abstract][Full Text] [Related]
3. Numerical investigation of turbulent diffusion in push-pull and exhaust fume cupboards.
Chern MJ; Cheng WY
Ann Occup Hyg; 2007 Aug; 51(6):517-31. PubMed ID: 17638713
[TBL] [Abstract][Full Text] [Related]
4. Effects of walk-by and sash movement on contaminant leakage of air curtain-isolated fume hood.
Huang RF; Chen HD; Hung CH
Ind Health; 2007 Dec; 45(6):804-16. PubMed ID: 18212476
[TBL] [Abstract][Full Text] [Related]
5. Required response time for variable air volume fume hood controllers.
Ekberg LE; Melin J
Ann Occup Hyg; 2000 Mar; 44(2):143-50. PubMed ID: 10717266
[TBL] [Abstract][Full Text] [Related]
6. Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics.
Huang RF; Wu YD; Chen HD; Chen CC; Chen CW; Chang CP; Shih TS
Ann Occup Hyg; 2007 Mar; 51(2):189-206. PubMed ID: 16857702
[TBL] [Abstract][Full Text] [Related]
7. Design considerations for fume hoods for process plants.
Goodfellow HD; Bender M
Am Ind Hyg Assoc J; 1980 Jul; 41(7):473-84. PubMed ID: 7415967
[TBL] [Abstract][Full Text] [Related]
8. Effects of doorsill jet injection on fume cupboard containment.
Tseng LC; Huang RF; Chen CC
Ann Occup Hyg; 2008 Oct; 52(7):635-44. PubMed ID: 18660505
[TBL] [Abstract][Full Text] [Related]
9. Development and characterization of a wake-controlled exterior hood.
Huang RF; Liu GS; Lin SY; Chen YK; Wang SC; Peng CY; Yeh WY; Chen CW; Chang CP
J Occup Environ Hyg; 2004 Dec; 1(12):769-78. PubMed ID: 15742706
[TBL] [Abstract][Full Text] [Related]
10. Application of a tracer gas challenge with a human subject to investigate factors affecting the performance of laboratory fume hoods.
Altemose BA; Flynn MR; Sprankle J
Am Ind Hyg Assoc J; 1998 May; 59(5):321-7. PubMed ID: 9858975
[TBL] [Abstract][Full Text] [Related]
11. Fume hood exhaust re-entry into a chemistry building.
Lamb BK; Cronn DR
Am Ind Hyg Assoc J; 1986 Feb; 47(2):115-23. PubMed ID: 3953421
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.
Dunn KH; Tsai CS; Woskie SR; Bennett JS; Garcia A; Ellenbecker MJ
J Occup Environ Hyg; 2014; 11(10):D164-73. PubMed ID: 25175285
[TBL] [Abstract][Full Text] [Related]
13. Containment testing of laboratory hoods in the as-used condition.
Greenley PL; Billings CE; DiBerardinis LJ; Edwards RW; Barkley WE
Appl Occup Environ Hyg; 2000 Feb; 15(2):209-16. PubMed ID: 10675979
[TBL] [Abstract][Full Text] [Related]
14. The effect of thermal loading on laboratory fume hood performance.
Johnston JD; Chessin SJ; Chesnovar BW; Lillquist DR
Appl Occup Environ Hyg; 2000 Nov; 15(11):863-8. PubMed ID: 11062932
[TBL] [Abstract][Full Text] [Related]
15. Effects of flange size on dividing streamlines of exterior hoods in cross drafts.
Huang RF; Liu GS; Chen YK; Yeh WY; Chen CW; Chen CC
J Occup Environ Hyg; 2004 May; 1(5):283-8. PubMed ID: 15238336
[TBL] [Abstract][Full Text] [Related]
16. Development of a push-pull ventilation system to control solder fume.
Watson SI; Cain JR; Cowie H; Cherrie JW
Ann Occup Hyg; 2001 Nov; 45(8):669-76. PubMed ID: 11718662
[TBL] [Abstract][Full Text] [Related]
17. Computational fluid dynamics as a method for assessing fume cupboard performance.
Nicholson GP; Clark RP; de Calcina-Goff ML
Ann Occup Hyg; 2000 May; 44(3):203-17. PubMed ID: 10775669
[TBL] [Abstract][Full Text] [Related]
18. [Evaluation of the reverse flow around a worker's body produced by a local exhaust hood].
Ojima J
Sangyo Eiseigaku Zasshi; 2003 Jul; 45(4):125-32. PubMed ID: 12968498
[TBL] [Abstract][Full Text] [Related]
19. Effects of sash movement and walk-bys on aerodynamics and contaminant leakage of laboratory fume cupboards.
Tseng LC; Huang RF; Chen CC; Chang CP
Ind Health; 2007 Apr; 45(2):199-208. PubMed ID: 17485863
[TBL] [Abstract][Full Text] [Related]
20. Fume hoods, open canopy type--their ability to capture pollutants in various environments.
Bender M
Am Ind Hyg Assoc J; 1979 Feb; 40(2):118-27. PubMed ID: 495443
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]