These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 9874819)

  • 21. Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed brachytherapy source.
    Kennedy RM; Davis SD; Micka JA; DeWerd LA
    Med Phys; 2010 Apr; 37(4):1681-8. PubMed ID: 20443489
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dosimetry of the 198Au source used in interstitial brachytherapy.
    Dauffy LS; Braby LA; Berner BM
    Med Phys; 2005 Jun; 32(6):1579-88. PubMed ID: 16013717
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Experimental determination of the dosimetric characteristics for the I-Plant model 3600 125I brachytherapy source.
    Tries MA; Mancevice CG; Munro JJ
    Med Phys; 2005 Jun; 32(6):1469-72. PubMed ID: 16013702
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
    Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
    Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
    Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Water equivalent phantom materials for ¹⁹²Ir brachytherapy.
    Schoenfeld AA; Harder D; Poppe B; Chofor N
    Phys Med Biol; 2015 Dec; 60(24):9403-20. PubMed ID: 26579946
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source--SmartSeed: dosimetric impact of fluorescence x rays.
    Abboud F; Hollows M; Scalliet P; Vynckier S
    Med Phys; 2010 May; 37(5):2054-62. PubMed ID: 20527538
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dosimetric characteristics of 192Ir sources used in interstitial brachytherapy.
    Ghiassi-Nejad M; Jafarizadeh M; Ahmadian-Pour MR; Ghahramani AR
    Appl Radiat Isot; 2001 Aug; 55(2):189-95. PubMed ID: 11393759
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dosimetric characteristics of the bests double-wall 103Pd brachytherapy source.
    Meigooni AS; Bharucha Z; Yoe-Sein M; Sowards K
    Med Phys; 2001 Dec; 28(12):2568-75. PubMed ID: 11797962
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources.
    Pérez-Calatayud J; Granero D; Casal E; Ballester F; Puchades V
    Med Phys; 2005 Jan; 32(1):28-36. PubMed ID: 15719951
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy.
    Wang R; Li XA
    Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms.
    Moura ES; Micka JA; Hammer CG; Culberson WS; DeWerd LA; Rostelato ME; Zeituni CA
    Med Phys; 2015 Apr; 42(4):1566-74. PubMed ID: 25832047
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vivo dosimeters for HDR brachytherapy: a comparison of a diamond detector, MOSFET, TLD, and scintillation detector.
    Lambert J; Nakano T; Law S; Elsey J; McKenzie DR; Suchowerska N
    Med Phys; 2007 May; 34(5):1759-65. PubMed ID: 17555257
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dosimetric characteristics of the Pharma Seed model BT-125-I source.
    Popescu CC; Wise J; Sowards K; Meigooni AS; Ibbott GS
    Med Phys; 2000 Sep; 27(9):2174-81. PubMed ID: 11011748
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of dosimetric parameters for various 192Ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation.
    Devan K; Aruna P; Manigandan D; Bharanidharan G; Subbaiah KV; Sunny CS; Ganesan S
    Med Dosim; 2007; 32(4):305-15. PubMed ID: 17980833
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Technical note: fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism.
    Lliso F; Pérez-Calatayud J; Carmona V; Ballester F; Puchades V; Granero D
    Med Phys; 2003 Apr; 30(4):651-4. PubMed ID: 12722817
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Verification of Ir-192 near source dosimetry using GAFCHROMIC film.
    Chiu-Tsao ST; Duckworth TL; Patel NS; Pisch J; Harrison LB
    Med Phys; 2004 Feb; 31(2):201-7. PubMed ID: 15000605
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of 103Pd-model Pd-1.
    Nath R; Yue N; Roa E
    Med Phys; 2002 Oct; 29(10):2433-4. PubMed ID: 12408318
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Equivalent phantom sizes and shapes for brachytherapy dosimetric studies of 192Ir and 137Cs.
    Granero D; Perez-Calatayud J; Pujades-Claumarchirant MC; Ballester F; Melhus CS; Rivard MJ
    Med Phys; 2008 Nov; 35(11):4872-7. PubMed ID: 19070221
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Monte Carlo dosimetry of the VariSource high dose rate 192Ir source.
    Wang R; Sloboda RS
    Med Phys; 1998 Apr; 25(4):415-23. PubMed ID: 9571607
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.