These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

61 related articles for article (PubMed ID: 9888199)

  • 1. Machining and accuracy studies for a tibial knee implant using a force-controlled robot.
    Van Ham G; Denis K; Vander Sloten J; Van Audekercke R; Van der Perre G; De Schutter J; Aertbeliën E; Demey S; Bellemans J
    Comput Aided Surg; 1998; 3(3):123-33. PubMed ID: 9888199
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Praxiteles: a miniature bone-mounted robot for minimal access total knee arthroplasty.
    Plaskos C; Cinquin P; Lavallée S; Hodgson AJ
    Int J Med Robot; 2005 Dec; 1(4):67-79. PubMed ID: 17518407
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An ABJS Best Paper: Dynamic intraoperative ligament balancing for total knee arthroplasty.
    D'Lima DD; Patil S; Steklov N; Colwell CW
    Clin Orthop Relat Res; 2007 Oct; 463():208-12. PubMed ID: 17960684
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved tibial cutting accuracy in knee arthroplasty.
    Macdonald W; Styf J; Carlsson LV; Jacobsson CM
    Med Eng Phys; 2004 Nov; 26(9):807-12. PubMed ID: 15564118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Haptic robotics enable a systems approach to design of a minimally invasive modular knee arthroplasty.
    Banks SA
    Am J Orthop (Belle Mead NJ); 2009 Feb; 38(2 Suppl):23-7. PubMed ID: 19340380
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect?
    Biant LC; Yeoh K; Walker PM; Bruce WJ; Walsh WR
    Knee; 2008 Jun; 15(3):238-41. PubMed ID: 18358725
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A surface-matching technique for robot-assisted registration.
    Glozman D; Shoham M; Fischer A
    Comput Aided Surg; 2001; 6(5):259-69. PubMed ID: 11892002
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tibiofemoral force following total knee arthroplasty: comparison of four prosthesis designs in vitro.
    Nicholls RL; Schirm AC; Jeffcote BO; Kuster MS
    J Orthop Res; 2007 Nov; 25(11):1506-12. PubMed ID: 17568418
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Alignment of resection planes in total knee replacement obtained with the conventional technique, as assessed by a modern computer-based navigation system.
    Belvedere C; Ensini A; Leardini A; Bianchi L; Catani F; Giannini S
    Int J Med Robot; 2007 Jun; 3(2):117-24. PubMed ID: 17619241
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Addition of a short central extension to surface cemented tibial trays in primary TKA: an in vitro study of the effect on initial fixation stability and its relationship to supporting bone density.
    Pérez-Blanca A; Prado M; Ezquerro F; Montañéz E; Espejo A
    Clin Biomech (Bristol); 2008 May; 23(4):483-92. PubMed ID: 18171597
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ligament balancing in TKA: evaluation of a force-sensing device and the influence of patellar eversion and ligament release.
    Crottet D; Kowal J; Sarfert SA; Maeder T; Bleuler H; Nolte LP; Dürselen L
    J Biomech; 2007; 40(8):1709-15. PubMed ID: 17094997
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimally invasive total knee arthroplasty: the importance of instrumentation.
    Tria AJ
    Orthop Clin North Am; 2004 Apr; 35(2):227-34. PubMed ID: 15062708
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical bone strength of the tibial resection surface at increasing distance from the joint line in total knee arthroplasty.
    Chaput CD; Weeden SH; Hyman WA; Hitt KD
    J Surg Orthop Adv; 2004; 13(4):195-8. PubMed ID: 15691179
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tibial plateau coverage in total knee arthroplasty.
    Incavo SJ; Ronchetti PJ; Howe JG; Tranowski JP
    Clin Orthop Relat Res; 1994 Feb; (299):81-5. PubMed ID: 8119041
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA.
    Crottet D; Maeder T; Fritschy D; Bleuler H; Nolte LP; Pappas IP
    IEEE Trans Biomed Eng; 2005 Sep; 52(9):1609-11. PubMed ID: 16189974
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A parametric analysis of fixation post shape in tibial knee prostheses.
    Au AG; Liggins AB; Raso VJ; Amirfazli A
    Med Eng Phys; 2005 Mar; 27(2):123-34. PubMed ID: 15642508
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Planning system for computer assisted total knee replacement.
    Müller W; Bockholt U; Voss G; Lahmer A; Börner M
    Stud Health Technol Inform; 2000; 70():214-9. PubMed ID: 10977543
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The dimensional accuracy for preparation of the femoral cavity in HIP arthroplasty. A comparison between manual- and robot-assisted implantation of hip endoprosthesis stems in cadaver femurs.
    Prymka M; Wu L; Hahne HJ; Koebke J; Hassenpflug J
    Arch Orthop Trauma Surg; 2006 Jan; 126(1):36-44. PubMed ID: 16341537
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty].
    Michaut M; Beaufils P; Galaud B; Abadie P; Boisrenoult P; Fallet L
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):580-4. PubMed ID: 18929753
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy.
    Yamazaki T; Watanabe T; Nakajima Y; Sugamoto K; Tomita T; Maeda D; Sahara W; Yoshikawa H; Tamura S
    Eur J Radiol; 2005 Jan; 53(1):84-9. PubMed ID: 15607857
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.