These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

225 related articles for article (PubMed ID: 9888200)

  • 21. NeuroSim--the prototype of a neurosurgical training simulator.
    Beier F; Diederich S; Schmieder K; Männer R
    Stud Health Technol Inform; 2011; 163():51-6. PubMed ID: 21335757
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Virtual image navigation: a new method to control intraoperative bleeding in neuroendoscopic surgery. Technical note.
    Scholz M; Fricke B; Tombrock S; Hardenack M; Schmieder K; von Düring M; Konen W; Harders A
    J Neurosurg; 2000 Aug; 93(2):342-50. PubMed ID: 10930024
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Image-guided neuroendoscopy].
    Moreau JJ; Ghorbel M; Moufid A; Hallacq P; Lagarrigue JF; Alibenali M; Vidal J
    Neurochirurgie; 2002 May; 48(2-3 Pt 1):92-6. PubMed ID: 12053163
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cadaveric and clinical study of endoscope-assisted microneurosurgery for cerebral aneurysms using angle-type rigid endoscope.
    Takaishi Y; Yamashita H; Tamaki N
    Kobe J Med Sci; 2002 Apr; 48(1-2):1-11. PubMed ID: 11912349
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Videoendoscopic distortion correction and its application to virtual guidance of endoscopy.
    Helferty JP; Zhang C; McLennan G; Higgins WE
    IEEE Trans Med Imaging; 2001 Jul; 20(7):605-17. PubMed ID: 11465467
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Robust registration procedures for endoscopic imaging.
    Konen W; Tombrock S; Scholz M
    Med Image Anal; 2007 Dec; 11(6):526-39. PubMed ID: 17584520
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Computer assisted localization in endoscopic sinus surgery--state of the art? The Insta Trak system].
    Luxenberger W; Köle W; Stammberger H; Reittner P
    Laryngorhinootologie; 1999 Jun; 78(6):318-25. PubMed ID: 10439350
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Computer-aided navigation for arthroscopic hip surgery using encoder linkages for position tracking.
    Monahan E; Shimada K
    Int J Med Robot; 2006 Sep; 2(3):271-8. PubMed ID: 17520642
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Calibration and accuracy testing for image-enhanced endoscopy.
    Bax MR; Khadem R; Johnson JA; Wilkinson EP; Shahidi R
    Stud Health Technol Inform; 2002; 85():52-6. PubMed ID: 15458059
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.
    Wolfsberger S; Neubauer A; Bühler K; Wegenkittl R; Czech T; Gentzsch S; Böcher-Schwarz HG; Knosp E
    Neurosurgery; 2006 Nov; 59(5):1001-9; discussion 1009-10. PubMed ID: 17143234
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Development of a camera model and calibration procedure for oblique-viewing endoscopes.
    Yamaguchi T; Nakamoto M; Sato Y; Konishi K; Hashizume M; Sugano N; Yoshikawa H; Tamura S
    Comput Aided Surg; 2004; 9(5):203-14. PubMed ID: 16192062
    [TBL] [Abstract][Full Text] [Related]  

  • 32. MRI-guided endoscopy in the brain: a feasability study.
    Scholz M; Deli M; Wildförster U; Wentz K; Recknagel A; Preuschoft H; Harders A
    Minim Invasive Neurosurg; 1996 Jun; 39(2):33-7. PubMed ID: 8811653
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Incorrect vector after calibration of surgical instruments for image guidance. The problem and the solution: technical note.
    Sure U; Hellwig D; Bertalanffy H
    Minim Invasive Neurosurg; 2001 Jun; 44(2):88-91. PubMed ID: 11487791
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A portable image overlay projection device for computer-aided open liver surgery.
    Gavaghan KA; Peterhans M; Oliveira-Santos T; Weber S
    IEEE Trans Biomed Eng; 2011 Jun; 58(6):1855-64. PubMed ID: 21411401
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Navigation systems based on registration of endoscopic and CT-derived virtual images for bronchofiberoscopic procedures.
    Turcza P; Duplaga M
    Stud Health Technol Inform; 2004; 105():253-63. PubMed ID: 15718614
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A new solution for camera calibration and real-time image distortion correction in medical endoscopy-initial technical evaluation.
    Melo R; Barreto JP; Falcão G
    IEEE Trans Biomed Eng; 2012 Mar; 59(3):634-44. PubMed ID: 22127990
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Future perspectives for intraoperative MRI.
    Jolesz FA
    Neurosurg Clin N Am; 2005 Jan; 16(1):201-13. PubMed ID: 15561539
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [A surgical navigation system based on C-arm fluoroscopy images].
    Qian L; Yan S; Xia Q; Wang C
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Oct; 26(5):1106-10. PubMed ID: 19947499
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Virtual neuroendoscopy, a comparative magnetic resonance and anatomical study.
    Burtscher J; Dessl A; Maurer H; Seiwald M; Felber S
    Minim Invasive Neurosurg; 1999 Sep; 42(3):113-7. PubMed ID: 10535292
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A theoretical comparison of 2-camera and 3-camera optical localizers with active or passive instrumentation.
    Faul I
    Stud Health Technol Inform; 1998; 50():284-90. PubMed ID: 10180555
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.