These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 9889898)

  • 1. Developing in vivo EPR oximetry for clinical use.
    Swartz HM; Walczak T
    Adv Exp Med Biol; 1998; 454():243-52. PubMed ID: 9889898
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The measurement of oxygen in vivo using EPR techniques.
    Swartz HM; Clarkson RB
    Phys Med Biol; 1998 Jul; 43(7):1957-75. PubMed ID: 9703059
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of anesthesia on cerebral tissue oxygen tension: use of EPR oximetry to make repeated measurements.
    Swartz HM; Taie S; Miyake M; Grinberg OY; Hou H; el-Kadi H; Dunn JF
    Adv Exp Med Biol; 2003; 530():569-75. PubMed ID: 14562753
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical electron paramagnetic resonance (EPR) oximetry using India ink.
    Williams BB; Khan N; Zaki B; Hartford A; Ernstoff MS; Swartz HM
    Adv Exp Med Biol; 2010; 662():149-56. PubMed ID: 20204785
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct and Repeated Measurement of Heart and Brain Oxygenation Using In Vivo EPR Oximetry.
    Khan N; Hou H; Swartz HM; Kuppusamy P
    Methods Enzymol; 2015; 564():529-52. PubMed ID: 26477264
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical EPR: unique opportunities and some challenges.
    Swartz HM; Williams BB; Zaki BI; Hartford AC; Jarvis LA; Chen EY; Comi RJ; Ernstoff MS; Hou H; Khan N; Swarts SG; Flood AB; Kuppusamy P
    Acad Radiol; 2014 Feb; 21(2):197-206. PubMed ID: 24439333
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Skeletal Muscle Oxygenation Measured by EPR Oximetry Using a Highly Sensitive Polymer-Encapsulated Paramagnetic Sensor.
    Hou H; Khan N; Nagane M; Gohain S; Chen EY; Jarvis LA; Schaner PE; Williams BB; Flood AB; Swartz HM; Kuppusamy P
    Adv Exp Med Biol; 2016; 923():351-357. PubMed ID: 27526163
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Repetitive tissue pO2 measurements by electron paramagnetic resonance oximetry: current status and future potential for experimental and clinical studies.
    Khan N; Williams BB; Hou H; Li H; Swartz HM
    Antioxid Redox Signal; 2007 Aug; 9(8):1169-82. PubMed ID: 17536960
    [TBL] [Abstract][Full Text] [Related]  

  • 9. EPR Oximetry for Investigation of Hyperbaric O2 Pre-treatment for Tumor Radiosensitization.
    Williams BB; Hou H; Coombs R; Swartz HM
    Adv Exp Med Biol; 2016; 923():367-374. PubMed ID: 27526165
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carbon-centered radicals as oxygen sensors for in vivo electron paramagnetic resonance: screening for an optimal probe among commercially available charcoals.
    Jordan BF; Baudelet C; Gallez B
    MAGMA; 1998 Dec; 7(2):121-9. PubMed ID: 9951772
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High spatial resolution multi-site EPR oximetry. The use of convolution-based fitting method.
    Grinberg OY; Smirnov AI; Swartz HM
    J Magn Reson; 2001 Oct; 152(2):247-58. PubMed ID: 11567578
    [TBL] [Abstract][Full Text] [Related]  

  • 12. What does EPR oximetry with solid particles measure--and how does this relate to other measures of PO2?
    Swartz HM; Dunn J; Grinberg O; O'Hara J; Walczak T
    Adv Exp Med Biol; 1997; 428():663-70. PubMed ID: 9500113
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of EPR oximetry and Eppendorf polarographic electrode assessments of rat brain PtO2.
    O'Hara JA; Khan N; Hou H; Wilmo CM; Demidenko E; Dunn JF; Swartz HM
    Physiol Meas; 2004 Dec; 25(6):1413-23. PubMed ID: 15712720
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Black magic and EPR oximetry: from lab to initial clinical trials.
    Khan N; Hou H; Hein P; Comi RJ; Buckey JC; Grinberg O; Salikhov I; Lu SY; Wallach H; Swartz HM
    Adv Exp Med Biol; 2005; 566():119-25. PubMed ID: 16594143
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using EPR to measure a critical but often unmeasured component of oxidative damage: oxygen.
    Swartz HM
    Antioxid Redox Signal; 2004 Jun; 6(3):677-86. PubMed ID: 15130295
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of biocompatible implants of fusinite for in vivo EPR oximetry.
    Gallez B; Debuyst R; Liu KJ; Demeure R; Dejehet F; Swartz HM
    MAGMA; 1996 Mar; 4(1):71-5. PubMed ID: 8774004
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of a clinically used charcoal suspension for in vivo EPR oximetry.
    Desmet CM; Tran LBA; Danhier P; Gallez B
    MAGMA; 2019 Apr; 32(2):205-212. PubMed ID: 30209636
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo electron paramagnetic resonance oximetry with particulate materials.
    Dunn JF; Swartz HM
    Methods; 2003 Jun; 30(2):159-66. PubMed ID: 12725782
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of pO2 in cultured mouse oocytes using electron paramagnetic resonance oximetry.
    Higaki S; Fujii H; Nagano M; Katagiri S; Takahashi Y
    Biomed Res; 2010 Apr; 31(2):165-8. PubMed ID: 20460746
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In Vivo pO2 Imaging of Tumors: Oxymetry with Very Low-Frequency Electron Paramagnetic Resonance.
    Epel B; Halpern HJ
    Methods Enzymol; 2015; 564():501-27. PubMed ID: 26477263
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.