These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
258 related articles for article (PubMed ID: 9914457)
1. An overview of the fifth-generation implantable cardioverter defibrillator. Tanaka S Ann Thorac Cardiovasc Surg; 1998 Dec; 4(6):303-11. PubMed ID: 9914457 [TBL] [Abstract][Full Text] [Related]
2. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators. Theuns D; Klootwijk AP; Kimman GP; Szili-Török T; Roelandt JR; Jordaens L Europace; 2001 Jul; 3(3):181-6. PubMed ID: 11467458 [TBL] [Abstract][Full Text] [Related]
3. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. Wilkoff BL; Williamson BD; Stern RS; Moore SL; Lu F; Lee SW; Birgersdotter-Green UM; Wathen MS; Van Gelder IC; Heubner BM; Brown ML; Holloman KK; J Am Coll Cardiol; 2008 Aug; 52(7):541-50. PubMed ID: 18687248 [TBL] [Abstract][Full Text] [Related]
4. Clinical experience with a new detection algorithm for differentiation of supraventricular from ventricular tachycardia in a dual-chamber defibrillator. Sinha AM; Stellbrink C; Schuchert A; Mox B; Jordaens L; Lamaison D; Gill J; Kaplan A; Merkely B; J Cardiovasc Electrophysiol; 2004 Jun; 15(6):646-52. PubMed ID: 15175058 [TBL] [Abstract][Full Text] [Related]
5. The implantable cardioverter defibrillator: technology, indications, and impact on cardiovascular survival. Bhatia A; Cooley R; Berger M; Blanck Z; Dhala A; Sra J; Axtell-Mcbride K; Vandervort C; Akhtar M Curr Probl Cardiol; 2004 Jun; 29(6):303-56. PubMed ID: 15159713 [TBL] [Abstract][Full Text] [Related]
6. [Clinical evaluation of a dual chamber implantable cardioverter-defibrillator]. Kazmierczak J; Tavernier R; De Sutter J; Jordaens L Pol Merkur Lekarski; 2000 Aug; 9(50):522-6. PubMed ID: 11081315 [TBL] [Abstract][Full Text] [Related]
7. Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients. Daubert JP; Zareba W; Hall WJ; Schuger C; Corsello A; Leon AR; Andrews ML; McNitt S; Huang DT; Moss AJ; J Am Coll Cardiol; 2006 Jan; 47(1):98-107. PubMed ID: 16386671 [TBL] [Abstract][Full Text] [Related]
8. Indications for dual-chamber cardioverter defibrillators at implant and at 1 year follow-up: a retrospective analysis in the single-chamber defibrillator era. Proclemer A; Della Bella P; Facchin D; Fattore L; Carbucicchio C; Tondo C; Lunati M; Vecchi MR; Petz E; Zecchin M Europace; 2001 Apr; 3(2):132-5. PubMed ID: 11333050 [TBL] [Abstract][Full Text] [Related]
9. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia. Chen RH; Chen KP; Wang FZ; Hua W; Chen X; Zhang S Chin Med J (Engl); 2006 Apr; 119(7):557-63. PubMed ID: 16620696 [TBL] [Abstract][Full Text] [Related]
10. Factors influencing appropriate firing of the implanted defibrillator for ventricular tachycardia/fibrillation: findings from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II). Singh JP; Hall WJ; McNitt S; Wang H; Daubert JP; Zareba W; Ruskin JN; Moss AJ; J Am Coll Cardiol; 2005 Nov; 46(9):1712-20. PubMed ID: 16256874 [TBL] [Abstract][Full Text] [Related]
11. Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation. Corbisiero R; Lee MA; Nabert DR; Coman JA; Breiter DJ; Schwartz M; McKittrick E; Zhang Y Europace; 2006 Dec; 8(12):1057-61. PubMed ID: 17105781 [TBL] [Abstract][Full Text] [Related]
13. Role of implantable cardioverter defibrillator therapy in the management of high-risk patients. Akhtar M; Avitall B; Jazayeri M; Tchou P; Troup P; Sra J; Axtell K Circulation; 1992 Jan; 85(1 Suppl):I131-9. PubMed ID: 1728496 [TBL] [Abstract][Full Text] [Related]
14. High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator. Korte T; Köditz H; Niehaus M; Paul T; Tebbenjohanns J Pacing Clin Electrophysiol; 2004 Jul; 27(7):924-32. PubMed ID: 15271011 [TBL] [Abstract][Full Text] [Related]
15. [The implantable cardioverter/defibrillator (ICD). Developments up to the present time and future perspectives]. Brachmann J; Hilbel T; Schöls W; Beyer T; Schweizer M; Sterns L; Karolyi L; Melichercik J; Freigang KD; Kübler W Herz; 1994 Oct; 19(5):246-50. PubMed ID: 8001897 [TBL] [Abstract][Full Text] [Related]
20. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]