BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

915 related articles for article (PubMed ID: 9917780)

  • 1. The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery.
    Hollick EJ; Spalton DJ; Ursell PG; Pande MV; Barman SA; Boyce JF; Tilling K
    Ophthalmology; 1999 Jan; 106(1):49-54; discussion 54-5. PubMed ID: 9917780
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Posterior capsular opacification with hydrogel, polymethylmethacrylate, and silicone intraocular lenses: two-year results of a randomized prospective trial.
    Hollick EJ; Spalton DJ; Ursell PG; Meacock WR; Barman SA; Boyce JF
    Am J Ophthalmol; 2000 May; 129(5):577-84. PubMed ID: 10844047
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification.
    Li N; Chen X; Zhang J; Zhou Y; Yao X; Du L; Wei M; Liu Y
    Ophthalmology; 2008 May; 115(5):830-8. PubMed ID: 17964657
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Neodymium:YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, and acrylic intraocular lenses.
    Ram J; Kaushik S; Brar GS; Gupta A
    Ophthalmic Surg Lasers; 2001; 32(5):375-82. PubMed ID: 11563781
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of posterior capsule opacification development with 3 intraocular lens types: five-year prospective study.
    Rönbeck M; Zetterström C; Wejde G; Kugelberg M
    J Cataract Refract Surg; 2009 Nov; 35(11):1935-40. PubMed ID: 19878826
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery.
    Vock L; Crnej A; Findl O; Neumayer T; Buehl W; Sacu S; Rainer G; Menapace R
    Am J Ophthalmol; 2009 Apr; 147(4):683-690.e2. PubMed ID: 19201391
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Relationship between intraocular lens biomaterials and posterior capsule opacification.
    Ursell PG; Spalton DJ; Pande MV; Hollick EJ; Barman S; Boyce J; Tilling K
    J Cataract Refract Surg; 1998 Mar; 24(3):352-60. PubMed ID: 9559471
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Nd : YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, or acrylic intra-ocular lenses in four European countries.
    Auffarth GU; Brezin A; Caporossi A; Lafuma A; Mendicute J; Berdeaux G; Smith AF;
    Ophthalmic Epidemiol; 2004 Oct; 11(4):319-29. PubMed ID: 15512993
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.
    Vock L; Menapace R; Stifter E; Georgopoulos M; Sacu S; Bühl W
    J Cataract Refract Surg; 2009 Mar; 35(3):459-65. PubMed ID: 19251138
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Silicone versus polymethylmethacrylate intraocular lenses with regard to capsular opacification.
    Olson RJ; Crandall AS
    Ophthalmic Surg Lasers; 1998 Jan; 29(1):55-8. PubMed ID: 9474601
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: five-year results of a randomized study.
    Sacu S; Menapace R; Findl O; Kiss B; Buehl W; Georgopoulos M
    Am J Ophthalmol; 2005 Apr; 139(4):696-703. PubMed ID: 15808167
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification.
    Ram J; Apple DJ; Peng Q; Visessook N; Auffarth GU; Schoderbek RJ; Ready EL
    Ophthalmology; 1999 May; 106(5):891-900. PubMed ID: 10328386
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: randomized clinical trial.
    Findl O; Menapace R; Sacu S; Buehl W; Rainer G
    Ophthalmology; 2005 Jan; 112(1):67-72. PubMed ID: 15629822
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Evaluation of the posterior capsule opacification in different types of artificial intraocular lenses].
    Pozlerová J; Nekolová J; Jirásková N; Rozsíval P
    Cesk Slov Oftalmol; 2009 Jan; 65(1):12-5. PubMed ID: 19366031
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: a randomized trial.
    Findl O; Buehl W; Menapace R; Sacu S; Georgopoulos M; Rainer G
    Ophthalmology; 2005 Nov; 112(11):2004-8. PubMed ID: 16168485
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-year follow-up of posterior capsule opacification with two different silicone intraocular lenses.
    Sundelin K; Shams H; Stenevi U
    Acta Ophthalmol Scand; 2005 Feb; 83(1):11-9. PubMed ID: 15715551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optic edge design as long-term factor for posterior capsular opacification rates.
    Kohnen T; Fabian E; Gerl R; Hunold W; Hütz W; Strobel J; Hoyer H; Mester U
    Ophthalmology; 2008 Aug; 115(8):1308-14, 1314.e1-3. PubMed ID: 18321585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantification of posterior capsule opacification with round and sharp edge intraocular lenses.
    Auffarth GU; Golescu A; Becker KA; Völcker HE
    Ophthalmology; 2003 Apr; 110(4):772-80. PubMed ID: 12689901
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: one-year follow-up.
    Kugelberg M; Wejde G; Jayaram H; Zetterström C
    J Cataract Refract Surg; 2006 Oct; 32(10):1627-31. PubMed ID: 17010858
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence on posterior capsule opacification and visual function of intraocular lens optic material.
    Hayashi K; Hayashi H
    Am J Ophthalmol; 2007 Aug; 144(2):195-202. PubMed ID: 17553447
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 46.