BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 9930417)

  • 1. Mitroflow pericardial bioprosthesis experience in aortic valve replacement > or =60 years of age.
    Pomar JL; Jamieson WR; Pelletier LC; Castellá M; Germann E; Brownlee RT
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S53-6. PubMed ID: 9930417
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CarboMedics Mitroflow pericardial aortic bioprosthesis - performance in patients aged 60 years and older after 15 years.
    Benhameid O; Jamieson WR; Castella M; Carrier M; Pomar JL; Germann E; Pellerin M; Brownlee RT
    Thorac Cardiovasc Surg; 2008 Jun; 56(4):195-9. PubMed ID: 18481236
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Carpentier-Edwards supraannular porcine bioprosthesis evaluation over 15 years.
    Jamieson WR; Ling H; Burr LH; Fradet GJ; Miyagishima RT; Janusz MT; Lichtenstein SV
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S49-52. PubMed ID: 9930416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Carpentier-Edwards standard porcine bioprosthesis: a 21-year experience.
    Jamieson WR; Burr LH; Munro AI; Miyagishima RT
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S40-3. PubMed ID: 9930414
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 15-year experience with the Carpentier-Edwards pericardial bioprosthesis.
    Poirer NC; Pelletier LC; Pellerin M; Carrier M
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S57-61. PubMed ID: 9930418
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Medtronic intact porcine bioprosthesis: 10 years' experience.
    Jamieson WR; Lemieux MD; Sullivan JA; Munro AI; Métras J; Cartier PC
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S118-21. PubMed ID: 9930430
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Durability after aortic valve replacement with the Mitroflow versus the Perimount pericardial bioprosthesis: a single-centre experience in 2393 patients.
    Nielsen PH; Hjortdal V; Modrau IS; Jensen H; Kimose HH; Terp K; Poulsen SH; Smerup M; Nielsen SL
    Eur J Cardiothorac Surg; 2016 Jun; 49(6):1705-10. PubMed ID: 26984983
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Italian study on the Mitroflow postoperative results (ISTHMUS): a 20-year, multicentre evaluation of Mitroflow pericardial bioprosthesis.
    ISTHMUS Investigators
    Eur J Cardiothorac Surg; 2011 Jan; 39(1):18-26; discussion 26. PubMed ID: 20621499
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term results of the Mitroflow aortic pericardial bioprosthesis in over 800 patients: limited durability and mechanisms of dysfunction.
    Ius F; Schulz J; Roumieh M; Fleissner F; Ismail I; Tudorache I; Warnecke G; Martens A; Shrestha M; Boethig D; Haverich A; Cebotari S
    Eur J Cardiothorac Surg; 2017 Aug; 52(2):264-271. PubMed ID: 28838100
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early calcification of the aortic Mitroflow pericardial bioprosthesis in the elderly.
    Alvarez JR; Sierra J; Vega M; Adrio B; Martinez-Comendador J; Gude F; Martinez-Cereijo J; Garcia J
    Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):842-6. PubMed ID: 19679611
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Seventeen-year clinical results of 1,037 Mitroflow pericardial heart valve prostheses in the aortic position.
    Yankah CA; Schubel J; Buz S; Siniawski H; Hetzer R
    J Heart Valve Dis; 2005 Mar; 14(2):172-9; discussion 179-80. PubMed ID: 15792176
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mitroflow aortic pericardial bioprosthesis--clinical performance.
    Jamieson WR; Koerfer R; Yankah CA; Zittermann A; Hayden RI; Ling H; Hetzer R; Dolman WB
    Eur J Cardiothorac Surg; 2009 Nov; 36(5):818-24. PubMed ID: 19700338
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients.
    McClure RS; Narayanasamy N; Wiegerinck E; Lipsitz S; Maloney A; Byrne JG; Aranki SF; Couper GS; Cohn LH
    Ann Thorac Surg; 2010 May; 89(5):1410-6. PubMed ID: 20417753
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Predictors of Survival and Modes of Failure After Mitroflow Aortic Valve Replacement in 1,003 Adults.
    Anantha Narayanan M; Suri RM; Ugur M; Greason KL; Stulak JM; Dearani JA; Joyce LD; Pochettino A; Li Z; Schaff HV
    Ann Thorac Surg; 2015 Aug; 100(2):560-7. PubMed ID: 25975942
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pericarbon pericardial valve prosthesis: midterm results of the aortic valve replacement.
    Borowiec JW; Dubiel TW; Hansson HE; Landelius J; Nyström SO
    Angiology; 1998 Jan; 49(1):1-11. PubMed ID: 9456159
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Early structural valve deterioration and reoperation associated with the mitroflow aortic valve.
    Axtell AL; Chang DC; Melnitchouk S; Jassar AS; Tolis G; Villavicencio MA; Sundt TM; D'Alessandro DA
    J Card Surg; 2018 Dec; 33(12):778-786. PubMed ID: 30525247
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Medtronic mosaic porcine bioprosthesis satisfactory early clinical performance.
    Thomson DJ; Jamieson WR; Dumesnil JG; Busse EF; Peniston CM; Métras J; Abel JG; Sullivan JA; Parrott JC
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S122-5. PubMed ID: 9930431
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Patient-prosthesis mismatch in patients undergoing bioprosthetic aortic valve implantation increases risk of reoperation for structural valve deterioration.
    Urso S; Calderón P; Sadaba R; Mahillo I; Tuñón J; Aldamiz G; Fraile J
    J Card Surg; 2014 Jul; 29(4):439-44. PubMed ID: 24773571
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Carpentier-Edwards pericardial bioprosthesis in aortic or mitral position: a 12-year experience.
    Neville PH; Aupart MR; Diemont FF; Sirinelli AL; Lemoine EM; Marchand MA
    Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S143-7. PubMed ID: 9930436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ten-year results of aortic valve replacement with first-generation Mitroflow bioprosthesis: is early degeneration a structural or a technical issue?
    Lootens L; Verbeke J; Martens T; Philipsen T; Caes F; Van Belleghem Y; Van Nooten G; François K; De Bacquer D; Bove T
    Eur J Cardiothorac Surg; 2017 Aug; 52(2):272-278. PubMed ID: 28430883
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.