187 related articles for article (PubMed ID: 9934412)
1. Evaluation of the anatomy of the common peroneal nerve. Defining nerve-at-risk in arthroscopically assisted lateral meniscus repair.
Deutsch A; Wyzykowski RJ; Victoroff BN
Am J Sports Med; 1999; 27(1):10-5. PubMed ID: 9934412
[TBL] [Abstract][Full Text] [Related]
2. Peroneal nerve dysfunction as a complication of lateral meniscus repair: a case report and anatomic dissection.
Jurist KA; Greene PW; Shirkhoda A
Arthroscopy; 1989; 5(2):141-7. PubMed ID: 2544194
[TBL] [Abstract][Full Text] [Related]
3. Common peroneal nerve neuropraxia after arthroscopic inside-out lateral meniscus repair.
Anderson AW; LaPrade RF
J Knee Surg; 2009 Jan; 22(1):27-9. PubMed ID: 19216349
[TBL] [Abstract][Full Text] [Related]
4. Zone-specific inside-out meniscal repair: technical limitations of repair of posterior horns of medial and lateral menisci.
Elkousy H; Higgins LD
Am J Orthop (Belle Mead NJ); 2005 Jan; 34(1):29-34. PubMed ID: 15707136
[TBL] [Abstract][Full Text] [Related]
5. Arthroscopic meniscal repair with use of the outside-in technique.
Rodeo SA
Instr Course Lect; 2000; 49():195-206. PubMed ID: 10829175
[TBL] [Abstract][Full Text] [Related]
6. An anatomical examination of iatrogenic nerve injury during inside out meniscus repair with flexion and extension of the knee.
Atbaşı Z; Erdem Y; Neyişci Ç; Yılmaz B; Demiralp B
Ulus Travma Acil Cerrahi Derg; 2019 Nov; 25(6):555-560. PubMed ID: 31701508
[TBL] [Abstract][Full Text] [Related]
7. The Risk of Iatrogenic Peroneal Nerve Injury in Lateral Meniscal Repair and Safe Zone to Minimize the Risk Based on Actual Arthroscopic Position: An MRI Study.
Chuaychoosakoon C; Boonsri P; Tanutit P; Laohawiriyakamol T; Boonriong T; Parinyakhup W
Am J Sports Med; 2022 Jun; 50(7):1858-1866. PubMed ID: 35532551
[TBL] [Abstract][Full Text] [Related]
8. Popliteal neurovascular bundle is safe during inside-out repair of medial meniscus without a safety incision.
Gupta H; Ghasi RG; Kataria H; Jain V; Shankar V; Daripa RK; Upadhyay AD
Knee Surg Sports Traumatol Arthrosc; 2019 Jan; 27(1):153-165. PubMed ID: 30019073
[TBL] [Abstract][Full Text] [Related]
9. The Effect of Knee Flexion Angle on the Neurovascular Safety of All-Inside Lateral Meniscus Repair: A Cadaveric Study.
Cuéllar A; Cuéllar R; Cuéllar A; Garcia-Alonso I; Ruiz-Ibán MA
Arthroscopy; 2015 Nov; 31(11):2138-44. PubMed ID: 26163307
[TBL] [Abstract][Full Text] [Related]
10. Common Peroneal Nerve Injury Due to an All-Inside Repair of the Posterior Horn of Lateral Meniscus: A Case Report.
Koiwa K; Oshiba H; Yamazaki H
JBJS Case Connect; 2023 Jan; 13(1):. PubMed ID: 36735799
[TBL] [Abstract][Full Text] [Related]
11. Proximity of the Neurovascular Bundle During Posterior-Lateral Meniscal Repair: A Comparison of the Transpatellar, Anteromedial, and Anterolateral Portals.
Massey P; Parker D; Feibel B; Ogden A; Robinson J; Barton RS
Arthroscopy; 2019 May; 35(5):1557-1564. PubMed ID: 31000388
[TBL] [Abstract][Full Text] [Related]
12. Peroneal nerve location at the fibular head: an anatomic study using 3D imaging.
Rausch V; Hackl M; Oppermann J; Leschinger T; Scaal M; Müller LP; Wegmann K
Arch Orthop Trauma Surg; 2019 Jul; 139(7):921-926. PubMed ID: 30737594
[TBL] [Abstract][Full Text] [Related]
13. [Meniscal plasty and suture repair for torn discoid lateral meniscus involving popliteal hiatus].
Dai Z; Chen J; Chen S; Chen Z; Fan W; Liao Y; Jiang J
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jan; 25(1):13-6. PubMed ID: 21351601
[TBL] [Abstract][Full Text] [Related]
14. Risk of iatrogenic injury to the peroneal nerve during posterolateral femoral tunnel placement in double-bundle anterior cruciate ligament reconstruction.
Hall MP; Ryzewicz M; Walsh PJ; Sherman OH
Am J Sports Med; 2009 Jan; 37(1):109-13. PubMed ID: 18952904
[TBL] [Abstract][Full Text] [Related]
15. Lesion of the common peroneal nerve during arthroscopy.
Krivić A; Stanec S; Zic R; Budi S; Milanović R; Stanec Z
Arthroscopy; 2003 Nov; 19(9):1015-8. PubMed ID: 14608324
[TBL] [Abstract][Full Text] [Related]
16. Risk to the lateral geniculate artery during arthroscopic lateral meniscal suture passage.
Chen NC; Martin SD; Gill TJ
Arthroscopy; 2007 Jun; 23(6):642-6. PubMed ID: 17560479
[TBL] [Abstract][Full Text] [Related]
17. Arthroscopic meniscus repair.
Warren RF
Arthroscopy; 1985; 1(3):170-2. PubMed ID: 3841638
[No Abstract] [Full Text] [Related]
18. Biomechanical consequences of a tear of the posterior root of the medial meniscus. Surgical technique.
Harner CD; Mauro CS; Lesniak BP; Romanowski JR
J Bone Joint Surg Am; 2009 Oct; 91 Suppl 2():257-70. PubMed ID: 19805589
[TBL] [Abstract][Full Text] [Related]
19. Proximal motor branches from the tibial nerve as direct donors to restore function of the deep fibular nerve for treatment of high sciatic nerve injuries: a cadaveric feasibility study.
Flores LP
Neurosurgery; 2009 Dec; 65(6 Suppl):218-24; discussion 224-5. PubMed ID: 19934998
[TBL] [Abstract][Full Text] [Related]
20. Selective deep peroneal nerve injury associated with arthroscopic knee surgery.
Esselman PC; Tomski MA; Robinson LR; Zisfein J; Marks SJ
Muscle Nerve; 1993 Nov; 16(11):1188-92. PubMed ID: 8413371
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]