These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 9934416)

  • 1. Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts.
    Magen HE; Howell SM; Hull ML
    Am J Sports Med; 1999; 27(1):35-43. PubMed ID: 9934416
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.
    Grover DM; Howell SM; Hull ML
    J Bone Joint Surg Am; 2005 Feb; 87(2):381-90. PubMed ID: 15687163
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model.
    Walsh MP; Wijdicks CA; Parker JB; Hapa O; LaPrade RF
    Am J Sports Med; 2009 Jan; 37(1):160-7. PubMed ID: 18832342
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Compaction of a bone dowel in the tibial tunnel improves the fixation stiffness of a soft tissue anterior cruciate ligament graft: an in vitro study in calf tibia.
    Howell SM; Roos P; Hull ML
    Am J Sports Med; 2005 May; 33(5):719-25. PubMed ID: 15722281
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of cyclic loading on the biomechanical characteristics of the femur-graft-tibia complex after anterior cruciate ligament reconstruction using Bone Mulch screw/WasherLoc fixation.
    Kudo T; Tohyama H; Minami A; Yasuda K
    Clin Biomech (Bristol, Avon); 2005 May; 20(4):414-20. PubMed ID: 15737449
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical comparison of 2 anterior cruciate ligament graft preparation techniques for tibial fixation: adjustable-length loop cortical button or interference screw.
    Mayr R; Heinrichs CH; Eichinger M; Coppola C; Schmoelz W; Attal R
    Am J Sports Med; 2015 Jun; 43(6):1380-5. PubMed ID: 25767269
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site.
    Kousa P; Järvinen TL; Vihavainen M; Kannus P; Järvinen M
    Am J Sports Med; 2003; 31(2):182-8. PubMed ID: 12642250
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading.
    Brown CH; Wilson DR; Hecker AT; Ferragamo M
    Arthroscopy; 2004 Nov; 20(9):922-35. PubMed ID: 15525925
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Suture versus screw fixation of displaced tibial eminence fractures: a biomechanical comparison.
    Bong MR; Romero A; Kubiak E; Iesaka K; Heywood CS; Kummer F; Rosen J; Jazrawi L
    Arthroscopy; 2005 Oct; 21(10):1172-6. PubMed ID: 16226643
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Foam-reinforced elderly human tibia approximates young human tibia better than porcine tibia: a study of the structural properties of three soft tissue fixation devices.
    Bailey SB; Grover DM; Howell SM; Hull ML
    Am J Sports Med; 2004; 32(3):755-64. PubMed ID: 15090394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim.
    Lenschow S; Schliemann B; Dressler K; Zampogna B; Vasta S; Raschke M; Zantop T
    Arch Orthop Trauma Surg; 2011 Aug; 131(8):1159-65. PubMed ID: 21667178
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: interference screw versus staple fixation in human knees.
    Gerich TG; Cassim A; Lattermann C; Lobenhoffer HP
    Knee Surg Sports Traumatol Arthrosc; 1997; 5(2):84-8. PubMed ID: 9228314
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of tibial graft fixation between simulated arthroscopic and open inlay techniques for posterior cruciate ligament reconstruction.
    Campbell RB; Torrie A; Hecker A; Sekiya JK
    Am J Sports Med; 2007 Oct; 35(10):1731-8. PubMed ID: 17554103
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis.
    Adam F; Pape D; Schiel K; Steimer O; Kohn D; Rupp S
    Am J Sports Med; 2004; 32(1):71-8. PubMed ID: 14754726
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tension band wire fixation for anterior cruciate ligament avulsion fracture: biomechanical comparison of four fixation techniques.
    Gan Y; Xu D; Ding J; Xu Y
    Knee Surg Sports Traumatol Arthrosc; 2012 May; 20(5):909-15. PubMed ID: 21863305
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of a safe range of knee flexion angles for fixation of the grafts in double-bundle anterior cruciate ligament reconstruction: a human cadaveric study.
    Vercillo F; Woo SL; Noorani SY; Dede O
    Am J Sports Med; 2007 Sep; 35(9):1513-20. PubMed ID: 17435061
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anterior cruciate ligament graft fixation. Comparison of hamstring and patellar tendon grafts.
    Steiner ME; Hecker AT; Brown CH; Hayes WC
    Am J Sports Med; 1994; 22(2):240-6; discussion 246-7. PubMed ID: 8198194
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation.
    Nagarkatti DG; McKeon BP; Donahue BS; Fulkerson JP
    Am J Sports Med; 2001; 29(1):67-71. PubMed ID: 11206259
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Screws or Sutures? A Pediatric Cadaveric Study of Tibial Spine Fracture Repairs.
    Johnstone TM; Baird DW; Cuellar-Montes A; van Deursen WH; Tompkins M; Ganley TJ; Yen YM; Ellis HB; Chan CK; Green DW; Sherman SL; Shea KG
    Am J Sports Med; 2023 Aug; 51(10):2589-2595. PubMed ID: 37382335
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.
    Thompson DM; Hull ML; Howell SM
    J Orthop Res; 2006 Sep; 24(9):1832-41. PubMed ID: 16865723
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.