These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 994312)

  • 41. Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber.
    Kim HC; Min BG
    ASAIO J; 1992; 38(4):846-50. PubMed ID: 1450484
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Hemodynamic responses to mechanical ventilation with PEEP: the effect of hypervolemia.
    Qvist J; Pontoppidan H; Wilson RS; Lowenstein E; Laver MB
    Anesthesiology; 1975 Jan; 42(1):45-55. PubMed ID: 234210
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Hemodynamic changes with posture in calves with total artificial heart.
    Fukamachi K; Fukumura F; Kiraly RJ; Massiello AL; Chen JF; Himley S; Davies C; Muramoto K; Olsen E; Golding LA
    ASAIO J; 1993; 39(3):M419-22. PubMed ID: 8268570
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Acute effects of dobutamine and isoproterenol after implantation of a total artificial heart.
    Cork RC; Gallo JA; Copeland JG
    J Heart Lung Transplant; 1992; 11(2 Pt 1):253-60. PubMed ID: 1576130
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Impact of Major Pulmonary Resections on Right Ventricular Function: Early Postoperative Changes.
    Elrakhawy HM; Alassal MA; Shaalan AM; Awad AA; Sayed S; Saffan MM
    Heart Surg Forum; 2018 Jan; 21(1):E009-E017. PubMed ID: 29485957
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Left ventricular performance and pulmonary circulation following addition of nitrous oxide to morphine during coronary-artery surgery.
    Lappas DG; Buckley MJ; Laver MB; Daggett WM; Lowenstein E
    Anesthesiology; 1975 Jul; 43(1):61-9. PubMed ID: 1147309
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Applications of total artificial heart for studies of circulatory physiology; measurement of resistance to venous return in postoperative awake calves. Preliminary report.
    Honda T; Fuqua JM; Edmonds CH; Hibbs CW; Akutsu T
    Ann Biomed Eng; 1976 Sep; 4(3):271-9. PubMed ID: 984533
    [No Abstract]   [Full Text] [Related]  

  • 48. Pulmonary hemodynamic responses to elevated cerebral spinal fluid pressure in the dog.
    Maron MB; Hakim TS; Dawson CA
    J Appl Physiol Respir Environ Exerc Physiol; 1979 Jan; 46(1):84-8. PubMed ID: 457535
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Effects of mechanical ventilation and spontaneous respiration on hemodynamics in calves with total artificial hearts.
    Fukamachi K; Irié H; Massiello A; Chen JF; Crouch R; Utoh J; Harasaki H; Golding LA; Kiraly RJ
    ASAIO J; 1992; 38(3):M493-6. PubMed ID: 1457909
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Effects of low-dose flosequinan on left ventricular systolic and diastolic chamber performance.
    Starling MR
    Am Heart J; 1994 Jul; 128(1):124-33. PubMed ID: 8017265
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Poor correlation between pulmonary arterial wedge pressure and left ventricular end-diastolic volume after coronary artery bypass graft surgery.
    Hansen RM; Viquerat CE; Matthay MA; Wiener-Kronish JP; DeMarco T; Bahtia S; Marks JD; Botvinick EH; Chatterjee K
    Anesthesiology; 1986 Jun; 64(6):764-70. PubMed ID: 3487261
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Peripheral vascular versus direct cardiac effects of calcium.
    Stanley TH; Isern-Amaral J; Liu WS; Lunn JK; Gentry S
    Anesthesiology; 1976 Jul; 45(1):46-58. PubMed ID: 937751
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Atrial and ventricular pressures in atrial flutter.
    Alboni P; Scarfò S; Fucà G; Paparella N; Mele D
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):600-4. PubMed ID: 10234713
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Evaluation of direct effects of enoximone on systemic and pulmonary vascular bed in animals with a Jarvik total artificial heart.
    Deleuze PH; Rande JL; Okude J; Wan F; Brunet S; Thoraval FR; Cachera JP; Loisance DY
    J Thorac Cardiovasc Surg; 1992 Mar; 103(3):589-94. PubMed ID: 1532041
    [TBL] [Abstract][Full Text] [Related]  

  • 55. In vitro performance investigation of SynCardia™ Freedom® driver via patient simulator mock loop.
    Toninato R; Scuri S; Tarzia V; Gerosa G; Susin FM
    Int J Artif Organs; 2016 Nov; 39(10):502-508. PubMed ID: 27768204
    [TBL] [Abstract][Full Text] [Related]  

  • 56. The right ventricle: interaction with the pulmonary circulation.
    Pinsky MR
    Crit Care; 2016 Sep; 20(1):266. PubMed ID: 27613549
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The effect of nitroglycerin upon pulmonary and left atrial pressures in patients with mitral stenosis.
    Rothbaum DA; Dillon JC; Feigenbaum H
    Am Heart J; 1976 Feb; 91(2):156-62. PubMed ID: 813508
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Effect of lactic acidosis on canine hemodynamics and left ventricular function.
    Teplinsky K; O'Toole M; Olman M; Walley KR; Wood LD
    Am J Physiol; 1990 Apr; 258(4 Pt 2):H1193-9. PubMed ID: 2331007
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Right-left ventricular balance in implanted electrically powered artificial hearts.
    Long JW; Khanwilkar P; Crump KR; Pantalos GM; Kinoshita M; Kim HC; Olsen DB
    ASAIO Trans; 1990; 36(3):M287-90. PubMed ID: 2252680
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Increased cardiac output following occlusion of the descending thoracic aorta in dogs.
    Stene JK; Burns B; Permutt S; Caldini P; Shanoff M
    Am J Physiol; 1982 Jul; 243(1):R152-8. PubMed ID: 7091388
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.