These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 994686)

  • 21. [Dynamics and contractility of the left ventricle].
    Krayenbühl H
    Bibl Cardiol; 1969; 23():1-183. PubMed ID: 4306950
    [No Abstract]   [Full Text] [Related]  

  • 22. Importance of pulmonary blood volume and aortic blood pressure in regulation of left ventricular function.
    Thorvaldson J
    J Oslo City Hosp; 1988; 38(5-7):45-59. PubMed ID: 2900297
    [No Abstract]   [Full Text] [Related]  

  • 23. [Effects of heart rate on maximal systolic pressure rise-velocity, stroke volume and relative depletion of the left canine ventricle].
    Limbourg P; Henrich H; Peiper U; Wende W
    Pflugers Arch; 1969; 312(1):R16. PubMed ID: 5390219
    [No Abstract]   [Full Text] [Related]  

  • 24. [Should one apply total or developed intraventricular pressure in the calculation of the isovolumetric pressure-velocity relationship of the left ventricle in man].
    Krayenbühl HP; Mehmel HC; Wirz P
    Arch Mal Coeur Vaiss; 1974 Nov; 67(11):1345-50. PubMed ID: 4218748
    [No Abstract]   [Full Text] [Related]  

  • 25. [Significance of quotient dp/dt max IP for the assessment of cardiac output].
    Raff U; Stauber W; Kissling G
    Z Kardiol; 1974 Dec; 63(12):1127-34. PubMed ID: 4617443
    [No Abstract]   [Full Text] [Related]  

  • 26. Functional reductions in left ventricular volume. Minimum chamber size consonant with effective hemodynamic performance.
    Liedtke AJ; Hughes HC; Zelis R
    J Thorac Cardiovasc Surg; 1976 Feb; 71(2):195-206. PubMed ID: 1246144
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Critical valuation of the washout method for the estimation of ventricular volume].
    Gülch R; Kissling G; Gack K; Jacob R
    Arztl Forsch; 1970 Oct; 24(10):281-9. PubMed ID: 4920103
    [No Abstract]   [Full Text] [Related]  

  • 28. [Pressure-volume relationship of the canine left ventricle (author's transl)].
    Suga H; Yamakoshi K
    Kokyu To Junkan; 1976 Apr; 24(4):291-9. PubMed ID: 945597
    [No Abstract]   [Full Text] [Related]  

  • 29. Time course of left ventricular pressure-volume relationship under various enddiastolic volume.
    Suga H
    Jpn Heart J; 1969 Nov; 10(6):509-15. PubMed ID: 5308142
    [No Abstract]   [Full Text] [Related]  

  • 30. [The curve of the intraventricular pressure-volume relationships is not mono-exponential].
    Donnet V; Peyrot J; Duflot JC; Havlik P; Fredenucci P; Fornaris M
    C R Seances Soc Biol Fil; 1976 Oct; 170(3):627-33. PubMed ID: 135623
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance of the right ventricle: a pressure plane analysis.
    Piene H; Sund T
    Cardiovasc Res; 1980 Apr; 14(4):217-22. PubMed ID: 7427969
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Left ventricular volume and cardiac output of the canine heart. Application of a mathematical two compartment model and a new dye dilution technique.
    Jarlov A; Mygind T; Christiansen ED
    Med Biol Eng; 1970 May; 8(3):221-39. PubMed ID: 4923588
    [No Abstract]   [Full Text] [Related]  

  • 33. Ventricular interference.
    Elzinga G; van Grondelle R; Westerhof N; van den Bos GC
    Am J Physiol; 1974 Apr; 226(4):941-7. PubMed ID: 4823057
    [No Abstract]   [Full Text] [Related]  

  • 34. Angiographic volume determination of the right ventricle.
    Lange PE; Onnasch D; Beurich HW; Heintzen PH
    Ann Radiol (Paris); 1978; 21(4-5):369-74. PubMed ID: 718101
    [No Abstract]   [Full Text] [Related]  

  • 35. Determinants of stroke volume in the isolated canine heart.
    Weber KT; Janicki JS; Reeves RC; Hefner LL; Reeves TJ
    J Appl Physiol; 1974 Nov; 37(5):742-7. PubMed ID: 4436201
    [No Abstract]   [Full Text] [Related]  

  • 36. [Proceedings: Relationship between momentary pressure and volume of the left heart ventricle].
    Kan H; Sagawa K
    Nihon Seirigaku Zasshi; 1974 Sep; 36(8-9):376. PubMed ID: 4478554
    [No Abstract]   [Full Text] [Related]  

  • 37. Selection of optimum cineradiographic frame rate: relation to accuracy of cardiac measurements.
    Bove AA; Ziskin MC; Freeman E; Gimenez JL; Lynch PR
    Invest Radiol; 1970; 5(5):329-35. PubMed ID: 5480826
    [No Abstract]   [Full Text] [Related]  

  • 38. Optimal control aspects of left ventricular ejection dynamics.
    Noldus EJ
    J Theor Biol; 1976 Dec; 63(2):275-309. PubMed ID: 1011846
    [No Abstract]   [Full Text] [Related]  

  • 39. [Hemodynamic and angiographic evaluation of right ventricle function].
    Marzocchi A; Marrozzini C; Sanguinetti M; Magnani B
    Cardiologia; 1986 Nov; 31(11):983-9. PubMed ID: 3829074
    [No Abstract]   [Full Text] [Related]  

  • 40. Microprocessor control of a ventricular volume servo-pump.
    Sunagawa K; Lim KO; Burkhoff D; Sagawa K
    Ann Biomed Eng; 1982; 10(4):145-59. PubMed ID: 7171150
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.