These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Complications of intracranial pressure monitoring in children with head trauma. Anderson RC; Kan P; Klimo P; Brockmeyer DL; Walker ML; Kestle JR J Neurosurg; 2004 Aug; 101(1 Suppl):53-8. PubMed ID: 16206972 [TBL] [Abstract][Full Text] [Related]
3. Maintaining CSF drainage at external ventricular drains may help prevent catheter-related infections. Razmkon A; Bakhtazad A Acta Neurochir (Wien); 2009 Aug; 151(8):985. PubMed ID: 19377850 [No Abstract] [Full Text] [Related]
4. Ventriculostomy: a guide to nursing management. Wisinger D; Mest-Beck L J Neurosci Nurs; 1990 Dec; 22(6):365-9. PubMed ID: 2148765 [TBL] [Abstract][Full Text] [Related]
5. Our policy on external ventricular drainage systems includes the procedure for priming the system. Does it really have to be primed? Littlejohns LR; Trimble B Crit Care Nurse; 2005 Jun; 25(3):57-9. PubMed ID: 15946929 [No Abstract] [Full Text] [Related]
6. External ventriculostomy: a practical application for the acute care nurse. Pope W J Neurosci Nurs; 1998 Jun; 30(3):185-90. PubMed ID: 9689610 [TBL] [Abstract][Full Text] [Related]
7. Third ventriculostomy through the lamina terminalis for intracranial pressure monitoring after aneurysm surgery: technical note. Kraemer JL; Gobbato PL; Andrade-Souza YM Arq Neuropsiquiatr; 2002 Dec; 60(4):932-4. PubMed ID: 12563383 [TBL] [Abstract][Full Text] [Related]
8. A survey of ventriculostomy and intracranial pressure monitor placement practices. O'Neill BR; Velez DA; Braxton EE; Whiting D; Oh MY Surg Neurol; 2008 Sep; 70(3):268-73; discussion 273. PubMed ID: 18207539 [TBL] [Abstract][Full Text] [Related]
9. Physicians are asking the nurses to irrigate ventriculostomy catheters . Kocan MJ Crit Care Nurse; 2002 Dec; 22(6):70-3. PubMed ID: 12518572 [No Abstract] [Full Text] [Related]
10. Risk factors and complications of intracranial pressure monitoring with a fiberoptic device. Bekar A; Doğan S; Abaş F; Caner B; Korfali G; Kocaeli H; Yilmazlar S; Korfali E J Clin Neurosci; 2009 Feb; 16(2):236-40. PubMed ID: 19071023 [TBL] [Abstract][Full Text] [Related]
15. Ventriculostomy and intracranial pressure monitoring: in search of a 0% infection rate. Bader MK; Littlejohns L; Palmer S Heart Lung; 1995; 24(2):166-72. PubMed ID: 7759277 [TBL] [Abstract][Full Text] [Related]
16. Is it an expected practice for critical care nurses to irrigate an external ventriculostomy drainage (EVD) system with tissue plasminogen activator (tPA) to break up blood clots in the tubing to facilitate drainage, thereby preventing increased intracranial pressure? Criddle LM Crit Care Nurse; 2007 Jun; 27(3):78, 80-1. PubMed ID: 17522194 [No Abstract] [Full Text] [Related]