These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
230 related articles for article (PubMed ID: 9951360)
1. [Pacemaker failure in elective DC cardioversion of atrial tachycardia]. Karlsen FM; Petersen L Ugeskr Laeger; 1999 Jan; 161(4):436-8. PubMed ID: 9951360 [TBL] [Abstract][Full Text] [Related]
2. [Failure of the pacemaker in electric cardioversion of atrial fibrillation]. Nielsen-Kudsk JE; Pedersen CM; Thomsen PE Ugeskr Laeger; 1992 Sep; 154(38):2571-2. PubMed ID: 1413185 [TBL] [Abstract][Full Text] [Related]
3. Adverse effects of direct current cardioversion on cardiac pacemakers and electrodes Is external cardioversion contraindicated in patients with permanent pacing systems? Waller C; Callies F; Langenfeld H Europace; 2004 Mar; 6(2):165-8. PubMed ID: 15018877 [TBL] [Abstract][Full Text] [Related]
4. [Selective increase of ventricular pacing threshold with complete exit block following DC cardioversion in a patient with a dual chamber pacemaker]. Dietl J; Grumbach H; Zrenner B; Sauer E Z Kardiol; 2002 Jan; 91(1):74-80. PubMed ID: 11963211 [TBL] [Abstract][Full Text] [Related]
6. [Abnormal pacing following defibrillation - exit block after microdislocation of the electrode (author's transl)]. Wehr M; Schmitt CG; Köhler F; Crayen P Z Kardiol; 1980 Dec; 69(12):840-4. PubMed ID: 7281867 [TBL] [Abstract][Full Text] [Related]
7. Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients. Altamura G; Bianconi L; Lo Bianco F; Toscano S; Ammirati F; Pandozi C; Castro A; Cardinale M; Mennuni M; Santini M Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 2):194-8. PubMed ID: 7724398 [TBL] [Abstract][Full Text] [Related]
8. Use of flecainide for refractory atrial tachycardia of pregnancy. Ahmed K; Issawi I; Peddireddy R Am J Crit Care; 1996 Jul; 5(4):306-8. PubMed ID: 8811156 [TBL] [Abstract][Full Text] [Related]
9. Ventricular capture by anodal pacemaker stimulation. Occhetta E; Bortnik M; Marino P Europace; 2006 May; 8(5):385-7. PubMed ID: 16636000 [TBL] [Abstract][Full Text] [Related]
10. Adverse acute and chronic effects of electrical defibrillation and cardioversion on implanted unipolar cardiac pacing systems. Levine PA; Barold SS; Fletcher RD; Talbot P J Am Coll Cardiol; 1983 Jun; 1(6):1413-22. PubMed ID: 6853897 [TBL] [Abstract][Full Text] [Related]
11. Outpatient cardioversion of atrial arrhythmias: efficacy, safety, and costs. Botkin SB; Dhanekula LS; Olshansky B Am Heart J; 2003 Feb; 145(2):233-8. PubMed ID: 12595839 [TBL] [Abstract][Full Text] [Related]
12. Orthodromic pacemaker-mediated tachycardia in a biventricular system without an atrial electrode. Berruezo A; Mont L; Scalise A; Brugada J J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1100-2. PubMed ID: 15363087 [TBL] [Abstract][Full Text] [Related]
13. Selective dysfunction of ventricular electrode-endocardial junction following DC cardioversion in a patient with a dual chamber pacemaker. Das G; Staffanson DB Pacing Clin Electrophysiol; 1997 Feb; 20(2 Pt 1):364-5. PubMed ID: 9058877 [TBL] [Abstract][Full Text] [Related]
14. Management of atrial fibrillation in the elderly. Aronow WS Minerva Med; 2009 Feb; 100(1):3-24. PubMed ID: 19182738 [TBL] [Abstract][Full Text] [Related]
15. Ventricular fibrillation following elective cardioversion in a patient with permanent pacemaker. Vera Z; Bommer WJ; Desai JM Pacing Clin Electrophysiol; 1990 May; 13(5):568-70. PubMed ID: 1693190 [TBL] [Abstract][Full Text] [Related]
16. Compromising bradycardia: management in the emergency department. Sodeck GH; Domanovits H; Meron G; Rauscha F; Losert H; Thalmann M; Vlcek M; Laggner AN Resuscitation; 2007 Apr; 73(1):96-102. PubMed ID: 17212976 [TBL] [Abstract][Full Text] [Related]
17. [Risks of electric cardioversion of tachyarrhythmia in patients with pacemakers]. Simonsen EH Ugeskr Laeger; 1992 Dec; 154(50):3610-2. PubMed ID: 1471285 [No Abstract] [Full Text] [Related]
18. External cardioversion of atrial fibrillation in patients with implanted pacemaker or cardioverter-defibrillator systems: a randomized comparison of monophasic and biphasic shock energy application. Manegold JC; Israel CW; Ehrlich JR; Duray G; Pajitnev D; Wegener FT; Hohnloser SH Eur Heart J; 2007 Jul; 28(14):1731-8. PubMed ID: 17569681 [TBL] [Abstract][Full Text] [Related]
19. Far-field R wave oversensing in dual chamber pacemakers designed for atrial arrhythmia management: effect of pacing site and lead tip to ring distance. Inama G; Santini M; Padeletti L; Boriani G; Botto G; Capucci A; Gulizia M; Ricci R; Rizzon P; Ferri F; Miraglia F; Raneri R; Grammatico A Pacing Clin Electrophysiol; 2004 Sep; 27(9):1221-30. PubMed ID: 15461712 [TBL] [Abstract][Full Text] [Related]