297 related articles for article (PubMed ID: 99807)
41. Over-estimation of glomerular filtration rate by single injection [51Cr]EDTA plasma clearance determination in patients with ascites.
Henriksen JH; Brøchner-Mortensen J; Malchow-Møller A; Schlichting P
Scand J Clin Lab Invest; 1980 May; 40(3):279-84. PubMed ID: 6777855
[TBL] [Abstract][Full Text] [Related]
42. Iohexol plasma clearance in determining glomerular filtration rate in diabetic patients.
Pucci L; Bandinelli S; Penno G; Nannipieri M; Rizzo L; Navalesi R
Ren Fail; 1998 Mar; 20(2):277-84. PubMed ID: 9574453
[TBL] [Abstract][Full Text] [Related]
43. Reference data for 51Cr-EDTA measurements of the glomerular filtration rate derived from live kidney donors.
Grewal GS; Blake GM
Nucl Med Commun; 2005 Jan; 26(1):61-5. PubMed ID: 15604949
[TBL] [Abstract][Full Text] [Related]
44. Cystatin C is a more sensitive marker than creatinine for the estimation of GFR in type 2 diabetic patients.
Mussap M; Dalla Vestra M; Fioretto P; Saller A; Varagnolo M; Nosadini R; Plebani M
Kidney Int; 2002 Apr; 61(4):1453-61. PubMed ID: 11918752
[TBL] [Abstract][Full Text] [Related]
45. [Correlation between four-hour creatinine clearance and 51Cr-EDTA test].
Peréz E; Ugarte C; Durruty P; Soto MC; Ayca V; Sotomayor G; Soledad Barría M
Rev Med Chil; 1995 May; 123(5):600-4. PubMed ID: 8525206
[TBL] [Abstract][Full Text] [Related]
46. Glomerular filtration rate measurement in cirrhotic patients with renal failure.
Roy L; Legault L; Pomier-Layrargues G
Clin Nephrol; 1998 Dec; 50(6):342-6. PubMed ID: 9877106
[TBL] [Abstract][Full Text] [Related]
47. Plasma clearance of iodine contrast media as a measure of glomerular filtration rate in critically ill patients.
Erley CM; Bader BD; Berger ED; Vochazer A; Jorzik JJ; Dietz K; Risler T
Crit Care Med; 2001 Aug; 29(8):1544-50. PubMed ID: 11505124
[TBL] [Abstract][Full Text] [Related]
48. Measurement of glomerular filtration rate.
Gaspari F; Perico N; Remuzzi G
Kidney Int Suppl; 1997 Dec; 63():S151-4. PubMed ID: 9407445
[TBL] [Abstract][Full Text] [Related]
49. Estimation of glomerular filtration rate in children using 99m-technetium DTPA. A comparison with 51-chromium EDTA clearance.
Yap HK; Sundram FX; Yip WC; Tay JS; Ang ES; Toh HJ; Joseph VT; Saw AH
Acta Paediatr Scand; 1985 Jul; 74(4):579-83. PubMed ID: 3927656
[TBL] [Abstract][Full Text] [Related]
50. Validation of plasma clearance of 51Cr-EDTA in adult renal transplant recipients: comparison with inulin renal clearance.
Medeiros FS; Sapienza MT; Prado ES; Agena F; Shimizu MH; Lemos FB; Buchpiguel CA; Ianhez LE; David-Neto E
Transpl Int; 2009 Mar; 22(3):323-31. PubMed ID: 19055616
[TBL] [Abstract][Full Text] [Related]
51. [Comparison of four methods for measuring glomerular filtration rate by inulin clearance in healthy individuals and patients with renal failure].
Hernández Ocampo J; Torres Rosales A; Rodríguez Castellanos F
Nefrologia; 2010; 30(3):324-30. PubMed ID: 20414326
[TBL] [Abstract][Full Text] [Related]
52. Individual determination of glomerular filtration rate from plasma creatinine.
Bröchner-Mortensen J; Tougaard L; Fynboe C; Thomsen HG
Scand J Clin Lab Invest; 1976 Jul; 36(4):389-93. PubMed ID: 822507
[TBL] [Abstract][Full Text] [Related]
53. Assessment of glomerular filtration rate in infants. Comparison of three methods used in clinical practice.
Alinei P; Guignard JP
Helv Paediatr Acta; 1987; 42(4):253-62. PubMed ID: 3443551
[TBL] [Abstract][Full Text] [Related]
54. Contrast media as markers of GFR.
Frennby B; Sterner G
Eur Radiol; 2002 Feb; 12(2):475-84. PubMed ID: 11870453
[TBL] [Abstract][Full Text] [Related]
55. GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe.
Brändström E; Grzegorczyk A; Jacobsson L; Friberg P; Lindahl A; Aurell M
Nephrol Dial Transplant; 1998 May; 13(5):1176-82. PubMed ID: 9623550
[TBL] [Abstract][Full Text] [Related]
56. Use of plasma clearance of inulin for estimating glomerular filtration rate in cats.
Brown SA; Haberman C; Finco DR
Am J Vet Res; 1996 Dec; 57(12):1702-5. PubMed ID: 8950421
[TBL] [Abstract][Full Text] [Related]
57. Long-term precision of glomerular filtration rate measurements using 51Cr-EDTA plasma clearance.
Blake GM; Roe D; Lazarus CR
Nucl Med Commun; 1997 Aug; 18(8):776-84. PubMed ID: 9293509
[TBL] [Abstract][Full Text] [Related]
58. Creatinine-based formulae for the estimation of glomerular filtration rate in heart transplant recipients.
Delanaye P; Nellessen E; Grosch S; Depas G; Cavalier E; Defraigne JO; Chapelle JP; Krzesinski JM; Lancellotti P
Clin Transplant; 2006; 20(5):596-603. PubMed ID: 16968485
[TBL] [Abstract][Full Text] [Related]
59. Conventional measurements of GFR using 51Cr-EDTA overestimate true renal clearance by 10 percent.
Moore AE; Park-Holohan SJ; Blake GM; Fogelman I
Eur J Nucl Med Mol Imaging; 2003 Jan; 30(1):4-8. PubMed ID: 12483403
[TBL] [Abstract][Full Text] [Related]
60. Comparison of 51Cr EDTA clearance with formulae in the measurement of glomerular filtration rate.
Sinton TJ; De Leacy EA; Cowley DM
Pathology; 1986 Oct; 18(4):445-7. PubMed ID: 3103081
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]