24. Pipeline for uncoilable or failed aneurysms: 3-year follow-up results. Becske T, Potts MB, Shapiro M, Kallmes DF, Brinjikji W, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosföi M, Cekirge SH, Nelson PK. J Neurosurg; 2017 Jul; 127(1):81-88. PubMed ID: 27739944 [Abstract] [Full Text] [Related]
25. Concomitant occurrence of clinoid and cavernous segment aneurysms complicated with carotid cavernous fistula: A case report. Ting W, Richard SA, Changwei Z, Chaohua W, Xiaodong X. Medicine (Baltimore); 2019 Nov; 98(48):e18184. PubMed ID: 31770272 [Abstract] [Full Text] [Related]
26. Delayed rupture of intracranial aneurysms after placement of intra-luminal flow diverter. Hou K, Li G, Lv X, Xu B, Xu K, Yu J. Neuroradiol J; 2020 Dec; 33(6):451-464. PubMed ID: 32851918 [Abstract] [Full Text] [Related]
27. Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center. Briganti F, Leone G, Cirillo L, de Divitiis O, Solari D, Cappabianca P. Neurosurg Focus; 2017 Jun; 42(6):E3. PubMed ID: 28565988 [Abstract] [Full Text] [Related]
28. Delayed Posttreatment Residual Flow into Aneurysm After Flow Diverter Placement. Nakae R, Takigawa T, Hirata K, Nagaishi M, Hyodo A, Suzuki K. World Neurosurg; 2018 Aug; 116():205-208. PubMed ID: 29852305 [Abstract] [Full Text] [Related]
29. Pipeline flow diversion of ruptured blister aneurysms of the supraclinoid carotid artery using a single-device strategy. Ryan RW, Khan AS, Barco R, Choulakian A. Neurosurg Focus; 2017 Jun; 42(6):E11. PubMed ID: 28565992 [Abstract] [Full Text] [Related]
30. Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases. Hampton T, Walsh D, Tolias C, Fiorella D. J Neurointerv Surg; 2018 Jul; 10(Suppl 1):i51-i55. PubMed ID: 30037958 [Abstract] [Full Text] [Related]
31. Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization device. Colby GP, Lin LM, Huang J, Tamargo RJ, Coon AL. J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii16-21. PubMed ID: 23516269 [Abstract] [Full Text] [Related]
32. Direct carotid-cavernous sinus fistula due to ruptured intracavernous aneurysm treated with electrodetachable coils--case report. Nishio A, Nishijima Y, Tsuruno T, Murata T, Hakuba A. Neurol Med Chir (Tokyo); 1999 Sep; 39(9):681-4. PubMed ID: 10563119 [Abstract] [Full Text] [Related]
33. Transvenous embolization of carotid-cavernous sinus fistula associated with a primitive trigeminal artery--case report. Oka Y, Sadamoto K, Tagawa M, Kumon Y, Sakaki S, Fujita M. Neurol Med Chir (Tokyo); 2000 Jan; 40(1):61-4. PubMed ID: 10721257 [Abstract] [Full Text] [Related]
34. Usefulness of intravascular ultrasonography monitoring of coil embolization for traumatic direct carotid-cavernous fistula-case report-. Nishio A, Kawakami T, Mitsuhashi Y, Hayasaki K, Kiyama M, Tada Y, Ohata K. Neurol Med Chir (Tokyo); 2009 Dec; 49(12):604-7. PubMed ID: 20035138 [Abstract] [Full Text] [Related]
35. Flow Diverter Therapy Using a Pipeline Embolization Device for 100 Unruptured Large and Giant Internal Carotid Artery Aneurysms in a Single Center in a Japanese Population. Oishi H, Teranishi K, Yatomi K, Fujii T, Yamamoto M, Arai H. Neurol Med Chir (Tokyo); 2018 Nov 15; 58(11):461-467. PubMed ID: 30298832 [Abstract] [Full Text] [Related]
36. Endovascular treatment of complex intracranial aneurysms by pipeline flow-diverter embolization device: a single-center experience. Keskin F, Erdi F, Kaya B, Poyraz N, Keskin S, Kalkan E, Ozbek O, Koc O. Neurol Res; 2015 Apr 15; 37(4):359-65. PubMed ID: 25310354 [Abstract] [Full Text] [Related]
37. Pipeline embolization device versus coiling for the treatment of large and giant unruptured intracranial aneurysms: a cost-effectiveness analysis. Wali AR, Park CC, Santiago-Dieppa DR, Vaida F, Murphy JD, Khalessi AA. Neurosurg Focus; 2017 Jun 15; 42(6):E6. PubMed ID: 28565986 [Abstract] [Full Text] [Related]
38. Recurrent carotico-cavernous fistula after internal carotid artery ligation: a case with embolization of the fistula via contralateral internal carotid artery approach. Dang NV, Hai NT, Cuong TC. Interv Neuroradiol; 2017 Jun 15; 20(4):482-6. PubMed ID: 25207912 [Abstract] [Full Text] [Related]
39. Endovascular treatment of a direct post-traumatic carotid-cavernous fistula with electrolytically detachable coils. Seruga T. Wien Klin Wochenschr; 2006 Jun 15; 118 Suppl 2():80-4. PubMed ID: 16817051 [Abstract] [Full Text] [Related]
40. Pipeline embolization device retraction and foreshortening after internal carotid artery blister aneurysm treatment. Heit JJ, Telischak NA, Do HM, Dodd RL, Steinberg GK, Marks MP. Interv Neuroradiol; 2017 Dec 15; 23(6):614-619. PubMed ID: 28758549 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]