These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Multiresidue gas chromatographic method for determining synthetic pyrethroid pesticides in agricultural products: collaborative study. Author: Pang GF, Cao YZ, Fan CL, Zhang JJ, Li XM. Journal: J AOAC Int; 1999; 82(1):186-212. PubMed ID: 10028687. Abstract: Fourteen laboratories from 6 countries and regions participated in an international collaborative study to evaluate a multiresidue gas chromatographic (GC) method for determining 8 synthetic pyrethroid pesticides in grains, fruits, and vegetables. The study design was based on Youden's matched-pairs principle for collaborative tests of analytical methods. Each laboratory analyzed 12 collaborative samples of wheat, oranges, and tomatoes as blind samples. Wheat samples were extracted with acetonitrile-water (2 + 1), while orange and tomato samples were extracted with acetone. Residues were partitioned into hexane, evaporated to dryness with a rotary evaporator, and then dissolved in hexane. The hexane extract was partitioned with acetonitrile and cleaned up on a 5% water-deactivated Florisil column with 6% ethyl ether in hexane as eluant. Residue concentrations were determined by GC with electron capture detection with splitless injection by comparison with single-point calibration standards. The appropriate standard concentration was determined by screening sample extracts before analysis. The multiresidue method was tested over the concentration range of 0.095-1.909 mg/kg depending on the 8 different of pesticides and agricultural products analyzed in the collaborative study. Statistical analysis of data from 13 laboratories showed weighted average recoveries for 8 pyrethroids in wheat, oranges, and tomatoes at 0.105-1.909, 0.095-1.909, and 0.105-0.954 mg/kg, respectively, ranging from 91.8 to 100.2%, from 88.1 to 100.6%, and from 88.2 to 101.5%, respectively. Reproducibility relative standard deviation values ranged from 6.46 to 17.74%, from 5.94 to 18.13%, and from 5.59 to 10.48%, respectively. Repeatability relative standard deviation values ranged from 6.34 to 10.84%, from 5.19 to 11.72%, and from 3.20 to 8.09%, respectively. The multiresidue GC method for determining synthetic pyrethroid pesticides in agricultural products has been adopted first action by AOAC INTERNATIONAL.[Abstract] [Full Text] [Related] [New Search]