These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Experience with one and a half ventricle repair. Author: Kreutzer C, Mayorquim RC, Kreutzer GO, Conejeros W, Roman MI, Vazquez H, Schlichter AJ, Kreutzer EA. Journal: J Thorac Cardiovasc Surg; 1999 Apr; 117(4):662-8. PubMed ID: 10096960. Abstract: OBJECTIVE: This article presents a 10-year experience with one and a half ventricle repair for right ventricular hypoplasia or dysfunction. METHODS: From November 1986 to December 1996, 30 patients (mean age 6.7 +/- 8.5 years, range 4 months-40 years) with functionally abnormal right ventricles underwent a bidirectional Glenn shunt as part of the repair. Diagnoses included pulmonary atresia with intact ventricular septum (n = 15), Ebstein anomaly (n = 5), levotransposition of the great arteries (n = 3), pulmonary stenosis with right ventricular hypoplasia (n = 2), tetralogy of Fallot (n = 3), dextrotransposition of the great arteries (n = l), and Uhl anomaly (n = l). Concomitantly performed cardiac procedures included atrial septal defect closure (n = 27), fenestration of the atrial septum (n = 2), right ventricular cavity augmentation (n = 8), right ventricular outflow tract enlargement (n = 6), transannular patch (n = 13), modified Blalock-Taussig shunt closure (n = 16), tricuspid replacement (n = 3), tricuspid repair (n = 2), Rastelli procedure (n = 3), tricuspid commissurotomy (n = 2), and double switch (n = l). RESULTS: There were 2 early deaths (6.6%) and 1 late death. Mean early postoperative superior vena caval pressure was 14. 12 +/- 3.55 mm Hg and mean right atrial pressure was 10.3 +/- 5.16 mm Hg. Early oxygen saturation in the operating room with an inspired oxygen fraction of 1 was 97.2 +/- 2.5; oxygen saturation was 92.3 +/- 4.8 on room air at discharge. Mean oxygen saturations were 93.6% +/- 3.6% at 1 year of follow-up (P =.10) and 93.5% +/- 4. 1% at 5 years (P =.12). Overall survival was 90% at 5 years, and 21 patients (77%) were in New York Heart Association class I, 5 (18%) were in class II, and 1 (2.7%) was in class III. CONCLUSION: This procedure provides a valid alternative for correction of right ventricle hypoplasia or dysfunction. Early and intermediate follow-up results compare favorably with those of the Fontan procedure, but long-term follow-up is needed.[Abstract] [Full Text] [Related] [New Search]