Title: A comparison of the accuracy of unit dose cart fill with the Baxter ATC-212 computerized system and manual filling. Author: Kratz K, Thygesen C. Journal: Hosp Pharm; 1992 Jan; 27(1):19-20, 22. PubMed ID: 10116118. Abstract: Pharmacy Service of the Department of Veteran Affairs Medical Center in Lincoln, Nebraska recently implemented a computerized Baxter ATC-212 Unit Dose System. During implementation of this system, pharmacy technicians completed an accuracy comparison with manual filling. The Baxter ATC-212 System was 99.98% accurate and manual filling was 92.62% accurate. The accuracy of the combination of manually and ATC-212 filled drawers was 98.77%. The technicians had a median error rate of three errors per day with an average 352 doses filled per day.[Abstract] [Full Text] [Related] [New Search]