These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Predictive value of PAI-1 plasma activity and thallium perfusion imaging for restenosis after percutaneous transluminal angioplasty in clinically asymptomatic patients.
    Author: Gottsauner-Wolf M, Sochor H, Hornykewycz S, Beckmann R, Lang I, Probst P, Binder BR, Huber K.
    Journal: Thromb Haemost; 1999 Apr; 81(4):522-6. PubMed ID: 10235432.
    Abstract:
    BACKGROUND: The main long-term complication of percutaneous transluminal coronary angioplasty (PTCA) is restenosis that occurs in 30-50 percent of all primary successful cases. The purpose of this study was to evaluate the predictive value of changes in plasminogen activator inhibitor-1 (PAI-1) activity and of thallium dipyridamole perfusion imaging performed 3 months after successful angioplasty. All patients were asymptomatic at evaluation. The results of these two noninvasive tests were compared with the angiographic outcome after 6 months. METHOD AND PATIENTS: Twenty-five patients were included in this prospective study. All patients had single vessel disease, successful angioplasty and were free of clinical symptoms 3 months after angioplasty that would suggest late restenosis. In 12/25 patients (48%) angiographic restenosis (percent diameter stenosis >50%) was determined by follow-up angiography 6 months after angioplasty. PAI-1 plasma activity was determined by a functional titration assay and increase or decrease of PAI-1 plasma activity was evaluated between values obtained before and 3 months after angioplasty. In 7/25 (28%) patients PAI-1 plasma activity increased to more than 90% of pre-angioplasty values. This increase correlated with angiographic restenosis evaluated 6 months after angioplasty (sensitivity 42%, specificity 85%, positive predictive value 71%, and negative predictive value 61%). T1-201-perfusion imaging was performed 3 months after angioplasty. This test was indicative for subsequent restenosis in 5/25 patients (sensitivity 33%, specificity 100%, positive predictive value 62%, and negative predictive value 100%). In 10/25 (40%) patients at least one of the two non-invasive tests performed 3 months after angioplasty predicted angiographic restenosis at 6 months: the combined use of PAI-1 and T1-201-perfusion imaging resulted in increased sensitivity (67%) and high specificity (85%). CONCLUSION: The results of this study indicate that an increase of PAI-1 plasma activity may improve the predictive value for restenosis of T1-201-scintigraphy performed 3 months after angioplasty even in asymptomatic patients.
    [Abstract] [Full Text] [Related] [New Search]