These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry. Author: Garway-Heath DF, Poinoosawmy D, Wollstein G, Viswanathan A, Kamal D, Fontana L, Hitchings RA. Journal: Br J Ophthalmol; 1999 Jun; 83(6):664-9. PubMed ID: 10340972. Abstract: AIMS: The development of imaging and measurement techniques has brought the prospect of greater objectivity in the measurement of optic disc features, and therefore better agreement between observers. The purpose of this study was to quantify and compare the variation between observers using two measurement devices. METHODS: Optic disc photographs and images from the Heidelberg retina tomograph (HRT) of 30 eyes of 30 subjects were presented to six observers for analysis, and to one observer on five separate occasions. Agreement between observers was studied by comparing the analysis of each observer with the median result of the other five, and expressed as the mean difference and standard deviation of differences between the observer and the median. Inter- and intraobserver variation was calculated as a coefficient of variation (mean SD/mean x 100). RESULTS: For planimetry, agreement between observers was dependent on observer experience, for the HRT it was independent. Agreement between observers (SD of differences as a percentage of the median) for optic disc area was 4.0% to 7.2% (planimetry) and 3.3% to 6.0% (HRT), for neuroretinal rim area it was 10.8% to 21.0% (planimetry) and 5.2% to 9.6% (HRT). The mean interobserver coefficient of variation for optic disc area was 8.1% (planimetry) and 4.4% (HRT), for neuroretinal rim area it was 16.3% (planimetry) and 8.1% (HRT), and (HRT only) for rim volume was 16.3%, and reference height 9.1%. HRT variability was greater for the software version 1.11 reference plane than for version 1.10. The intraobserver coefficient of variation for optic disc area was 1.5% (planimetry) and 2.4% (HRT), for neuroretinal rim area it was 4.0% (planimetry) and 4.5% (HRT). CONCLUSIONS: Variation between observers is greatly reduced by the HRT when compared with planimetry. However, levels of variation, which may be clinically significant, remain for variables that depend on the subjective drawing of the disc margin.[Abstract] [Full Text] [Related] [New Search]