These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Oxygen-enhanced magnetic resonance ventilation imaging of the human lung at 0.2 and 1.5 T. Author: Stock KW, Chen Q, Morrin M, Hatabu H, Edelman RR. Journal: J Magn Reson Imaging; 1999 Jun; 9(6):838-41. PubMed ID: 10373032. Abstract: Lung ventilation imaging using inhaled oxygen as a contrast medium was performed using both a 0.2 and a 1.5 T clinical magnetic resonance (MR) scanner in eight volunteers. Signal-to-noise-ratios (SNRs) of the ventilation images as well as T1 values of the lung acquired with inhalation of 100% oxygen and room air were calculated. The SNR was 9.7 +/- 3.0 on the 0.2 T MR system and 69.5 +/- 28.8 on the 1.5 T system (P < 0.001). The mean T1 value on the 0.2 T MR system with subjects breathing room air was 632 +/- 54 msec; with 100% oxygen, it was 586 +/- 41 msec (P < 0.01). At 1.5 T, the mean values were 904 +/- 99 msec and 790 +/- 114 msec, respectively (P < 0.0001). We conclude that MR oxygen-enhanced ventilation imaging of the lung is feasible with an open configured 0.2 T MR system.[Abstract] [Full Text] [Related] [New Search]