These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments. Author: Keith SE, Miller BH, Woody RD, Higginbottom FL. Journal: Int J Oral Maxillofac Implants; 1999; 14(3):369-78. PubMed ID: 10379110. Abstract: This in vitro study quantified the marginal discrepancy of the implant-to-prosthetic-crown interface on nonsubmerged dental implants restored with either a cemented or a screw-retained approach. Metal-ceramic crowns were fabricated for 20 ITI 4.1 x 10 mm solid-screw titanium implants. Ten implants received octa abutments and screw-retained crowns fabricated on premachined gold cylinders. The remaining 10 implants were restored with 5.5-mm solid abutments and metal-ceramic crowns cemented alternately with a glass-ionomer or a zinc phosphate luting agent. Inspection of the implant-crown interface was conducted using light microscopy under x 50 magnification at selected stages in the process of crown fabrication. Statistical analysis revealed a significant difference (P < .001) in the mean marginal fit between screw-retained (8.5 +/- 5.7 microns) and luted implant-supported crowns. This difference was observed both before (54.4 +/- 18.1 microns) and after cementation with glass-ionomer (57.4 +/- 20.2 microns) or zinc phosphate (67.4 +/- 15.9 microns).[Abstract] [Full Text] [Related] [New Search]