These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Exercise-test Tc-99m tetrofosmin SPECT in patients with chronic ischemic left ventricular dysfunction: direct comparison with Ti-201 reinjection.
    Author: Nicolai E, Cuocolo A, Acampa W, Varrone A, Pace L, Salvatore M.
    Journal: J Nucl Cardiol; 1999; 6(3):270-7. PubMed ID: 10385182.
    Abstract:
    BACKGROUND: This study was designed to compare the results of exercise-rest technetium-99m tetrofosmin single photon emission computed tomography (SPECT) with those of thallium-201 reinjection at rest after exercise-redistribution imaging in the same patients with chronic ischemic left ventricular (LV) dysfunction. METHODS: Within 1 week, 33 patients with chronic myocardial infarction and LV dysfunction underwent exercise-rest tetrofosmin SPECT and Tl-201 reinjection at rest after exercise-redistribution imaging. In each patient, regional tetrofosmin and Tl-201 activity was quantitatively measured in 22 myocardial segments. Regional LV function was assessed in corresponding segments by echocardiography. RESULTS: Agreement in the evaluation of regional perfusion status between tetrofosmin and Tl-201 imaging was observed in 78% of the 726 total segments, with a kappa value of 0.61. In segments with normal function at echocardiography (n = 436), no difference between Tl-201 and tetrofosmin uptake was observed. In hypokinetic segments (n = 138), exercise tetrofosmin uptake was lower (P < .01) as compared with exercise Tl-201 activity, whereas no difference was observed between tetrofosmin uptake at rest as compared with Tl-201 activity on redistribution and reinjection images. In segments with severe functional impairment (akinetic or dyskinetic, n = 152), tetrofosmin uptake on exercise images was reduced (P < .01) as compared with exercise Tl-201 activity; furthermore, tetrofosmin uptake at rest was lower (P < .01) as compared with Tl-201 activity on both redistribution and reinjection images. In these segments, concordance in the detection of myocardial viability between tetrofosmin and Tl-201 imaging was observed in 138 (91%) of the 152 segments, with a kappa value of 0.77. CONCLUSIONS: In patients with chronic coronary artery disease and LV dysfunction quantitative exercise-rest tetrofosmin and Tl-201 reinjection SPECT provide similar information in the assessment of perfusion status and in the detection of myocardial viability.
    [Abstract] [Full Text] [Related] [New Search]