  • Title: [Successful management of a patient with pulmonary arteriovenous fistula using a continuous intra-arterial blood gas monitoring system].
    Author: Habuka K, Ishikawa S, Makita K.
    Journal: Masui; 1999 Jun; 48(6):647-9. PubMed ID: 10402819.
    Abstract:
    We successfully anesthetized a patient with pulmonary arteriovenous fistula who received partial pulmonary resection and pulmonary arteriovenous plastic operation under one lung ventilation anesthesia, using a continuous intra-arterial blood gas monitoring system. During anesthesia including one lung ventilation, the patient did not experience any fatal hypoxemia. The continuous intra-arterial blood gas monitoring system was useful in a patient with pulmonary arteriovenous fistula under one lung ventilation anesthesia.