These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Validity of cardiotocography in the detection of umbilical cord complications]. Author: Troeger C, Briese V, Müller H. Journal: Zentralbl Gynakol; 1999; 121(5):233-8. PubMed ID: 10408075. Abstract: OBJECTIVE: The purpose of this study was to investigate the validity of cardiotocography for the detection of cord complications. MATERIAL AND METHODS: A low-risk population of 4196 cases was selected in which cord complications have been recognized in 34.3%. Cases with cord complications and controls were paired by parity, gestational age, maternal age and mode of delivery. 25 pairs were randomly selected. 50 tracings were presented twice to 4 obstetricians in a double-blind manner. As parameters for the determination of the validity of fetal monitoring the reliability, positive (ppv) and negative predictive value (npv), sensitivity and specificity were used. Inter- and intra-observer variability were also examined. RESULTS: Reliability 52%, ppv 52%, npv 52%, sensitivity 46%, specificity 58%. Interobserver variability: All 4 obstetricians agreed in 47 of 100 evaluations. The level of agreement was higher in the controls (63%) than in the cord complication group (56%). The intraobserver variability was 25%. CONCLUSIONS: Cardiotocography is not useful for the detection of cord complications. The range of possibilities has not been exploited yet, even for the evaluation of the fetal state.[Abstract] [Full Text] [Related] [New Search]