These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Improved detection of radiofrequency current-induced minor myocardial injury by cardiac troponin T measurement. Author: Sribhen K, Bhuripanyo K, Raungratanaamporn O, Kiartivich S, Leowattana W, Chaithiraphan S. Journal: J Med Assoc Thai; 1999 Mar; 82(3):256-62. PubMed ID: 10410480. Abstract: Transcatheter radiofrequency current application in patients with cardiac arrhythmias was reported to be associated with a low rate of an increase in the activity of enzyme creatine kinase (CK) and CK-MB isoenzyme. As the novel heart-specific protein troponin T (cTnT) was shown to be superior to CK and CK-MB in detecting small damage to myocardial tissue in various clinical situations including unstable angina, a comparison of the diagnostic efficiency of these marker proteins to detect myocardial damage was made in 34 patients (mean age 38.3 +/- 15.6 years) undergoing radiofrequency (RF) catheter ablation of accessory pathways (n = 17) and atrioventricular nodal reentrant tachycardia (n = 17). Serial measurements of total CK and CK-MB activity before and every 8 hours for 24 hours after ablative procedure were performed with enzymatic and immunoinhibition method, respectively, using automated chemical analyzer Hitachi 717. Serum concentration of cTnT was determined by one-step sandwich ELISA performed on ES 300 analyzer (Boehringer Mannheim). With a median of 7.0 (range 1-39) RF current pulses only 12 (35%) and 10 (29%) of 34 patients showed an increase above the upper limit of normal CK and CK-MB activity, respectively. The peak activity of CK (mean peak = 285.8 +/- 517.7 IU/L) occurred at a variable time that infrequently coincided with those of peak CK-MB activity (23.1 +/- 8.0 IU/L). By contrast, all except 4 (88%) of 34 patients exhibited a distinct elevation of cTnT concentration (mean peak = 0.56 +/- 0.63 ng/ml), with almost all (33) of these 34 patients showed an early peak value at 8 hours postprocedural. There was, on the average, a small but distinct higher relative increase (5.6 times) in cTnT concentration from the upper limit of reference range compared with those of CK (1.5 times) and CK-MB peak activity (0.9 time). In conclusion, cTnT exhibited a minor but distinct elevation in its concentration and demonstrated a higher rate and magnitude of increase following radiofrequency current application than the conventional CK and CK-MB isoenzyme. Measurements of cTnT serum concentration may thus provide a useful test method for assessing the effect of the new transcatheter ablation procedures on myocardial tissue.[Abstract] [Full Text] [Related] [New Search]