These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Flow cytometric detection of antigen-specific cytokine responses in lung T cells in a murine model of pulmonary inflammation.
    Author: Winterrowd GE, Chin JE.
    Journal: J Immunol Methods; 1999 Jun 24; 226(1-2):105-18. PubMed ID: 10410976.
    Abstract:
    Multiparameter flow cytometry was used to examine the cytokine responses of antigen-specific T lymphocytes isolated from the lungs of antigen-sensitized mice which developed pulmonary inflammation after aerosol challenge with ovalbumin (OA) (OA/OA). Lung T cells were stimulated in vitro with OA and anti-CD28 monoclonal antibody (mAb) in the presence of the secretion inhibitor, brefeldin A. T cell subsets were examined for intracellular cytokine expression using fluorochrome-labeled cell-surface specific and anti-cytokine antibodies. Antigen-specific responses resulted in significant numbers of CD4+ lung cells expressing cytoplasmic interleukin (IL)-2 (6%), IL-4 (1.5%), IL-5 (4%), and tumor necrosis factor (TNF)-alpha (11%), but not interferon (IFN)-gamma. Dual cytokine analyses demonstrated antigen-specific responses resulted in CD4+ T cells being positive for IL-2 and IL-4 or IL-2 and IL-5. TNF-alpha was the only antigen-specific cytokine response detected in CD8+ lung T cells after in vitro activation with OA. Cytokines in the supernatants of cultures activated with OA and anti-CD28 were measured by ELISA and the results confirmed the antigen-specific responses measured by flow cytometry. Polyclonal activation of lung T cells from OA/OA mice with 12-myristate 13-acetate (PMA), ionomycin, anti-CD3 mAb, and anti-CD28 mAb resulted in higher percentages of IL-2+ (43%) and IL-5+ (7%) CD4 cells when compared to CD4+ T cells from non-OA sensitized, challenged mice. CD8+ cells from OA/OA mice demonstrated intracellular staining for IL-2 (26%), TNF-alpha (55%), and IFN-gamma (37%), but not IL-4 or IL-5, after polyclonal activation. There is less agreement between intracellular cytokine staining of CD4+ T cells and cytokines released into the culture medium after polyclonal activation. Dual cytokine analyses of polyclonal-activated CD4+ cells demonstrated co-expression of IFN-gamma with IL-2, IL-4, or IL-5. T cells co-expressing IL-2 with IL-4 or IL-5 were also detected. These results demonstrate the utility of multiparameter flow cytometry to directly measure antigen-specific cytokine responses in subsets of T lymphocytes isolated from inflammatory sites.
    [Abstract] [Full Text] [Related] [New Search]