  • Title: Asbestos fiber release from the brake pads of overhead industrial cranes.
    Author: Spencer JW, Plisko MJ, Balzer JL.
    Journal: Appl Occup Environ Hyg; 1999 Jun; 14(6):397-402. PubMed ID: 10429735.
    Abstract:
    The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibers were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranged from < 0.005 to 0.011 fibers/cc (PCM), and < 0.0026 to < 0.0094 f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.