These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Indoor-air quality and ocular discomfort.
    Author: Backman H, Haghighat F.
    Journal: J Am Optom Assoc; 1999 May; 70(5):309-16. PubMed ID: 10457708.
    Abstract:
    BACKGROUND: Almost 25 million workers in 1.2 million commercial buildings in the United States have symptoms of sick building syndrome (SBS). It is a source of ocular discomfort and may exacerbate the successful wear of contact lenses. This study examines the relationship between SBS and oculovisual discomfort. METHODS: Measurements of carbon dioxide, formaldehyde, temperature, and humidity were performed in 12 public office buildings that contained a total of 877 occupants. A questionnaire survey of the occupants was also performed. RESULTS: Thirty-five percent of the occupants of the buildings were dissatisfied with the indoor-air quality. Twenty-nine percent of the office building occupants reported ocular discomfort. CONCLUSION: There was a significant correlation between eye irritation, throat irritation, and symptoms of blurred near vision. Ocular discomfort could be an indicator of poor indoor-air quality and a sick building syndrome.
    [Abstract] [Full Text] [Related] [New Search]