These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of physiological and simple pulsatile flows through stenosed arteries. Author: Zendehbudi GR, Moayeri MS. Journal: J Biomech; 1999 Sep; 32(9):959-65. PubMed ID: 10460133. Abstract: Most experimental and numerical studies of pulsatile flow through stenosed arteries have been performed for a first harmonic oscillatory flow. In this paper, numerical solutions are presented for a physiological pulsatile flow as well as for an equivalent simple pulsatile flow, having the same stroke volume as the physiological flow, and the differences in their flow behavior are discussed. The analysis is restricted to laminar flow, Newtonian fluid and axisymmetric rigid stenosis. Comparison of results shows that the behaviors of the two flows are similar at some instances of time, however, important observed differences indicate that for thorough understanding of pulsatile flow behavior in stenosed arteries, the actual physiological flow should be simulated.[Abstract] [Full Text] [Related] [New Search]