These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluation of slice shear force as an objective method of assessing beef longissimus tenderness.
    Author: Shackelford SD, Wheeler TL, Koohmaraie M.
    Journal: J Anim Sci; 1999 Oct; 77(10):2693-9. PubMed ID: 10521029.
    Abstract:
    Experiments were conducted to develop an optimal protocol for measurement of slice shear force (SSF) and to evaluate SSF as an objective method of assessing beef longissimus tenderness. Whereas six cylindrical, 1.27-cm-diameter cores are typically removed from each steak for Warner-Bratzler shear force (WBSF) determination, a single 1-cm-thick, 5-cm-long slice is removed from the lateral end of each longissimus steak for SSF. For either technique, samples are removed parallel to the muscle fiber orientation and sheared across the fibers. Whereas WBSF uses a V-shaped blade, SSF uses a flat blade with the same thickness (1.016 mm) and degree of bevel (half-round) on the shearing edge. In Exp. 1, longissimus steaks were acquired from 60 beef carcasses to determine the effects of belt grill cooking rate (very rapid vs. rapid) and conditions of SSF measurement (hot vs cold) on the relationship of SSF with trained sensory panel (TSP) tenderness rating. Slice shear force was more strongly correlated with TSP tenderness rating when SSF measurement was conducted immediately after cooking (r = -.74 to -.76) than when steaks were chilled (24 h, 4 degrees C) before SSF measurement (r = -.57 to -.72). When SSF measurement was conducted immediately after cooking, the relationship of SSF with TSP tenderness rating did not differ among the belt grill cooking protocols used to cook the SSF steak. In Exp. 2, longissimus steaks were acquired from 479 beef carcasses to compare the ability of SSF and WBSF of 1.27-cm-diameter cores to predict TSP tenderness ratings. Slice shear force was more strongly correlated with sensory panel tenderness rating than was WBSF (r = -.82 vs -.77). In Exp. 3, longissimus steaks were acquired from 110 beef carcasses to evaluate the repeatability (.91) of SSF over a broad range of tenderness. Slice shear force is a more rapid, more accurate, and technically less difficult technique than WBSF. Use of the SSF technique could facilitate the collection of more accurate data and should allow the detection of treatment differences with reduced numbers of observations and reduced time requirements, thereby reducing research costs.
    [Abstract] [Full Text] [Related] [New Search]