These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Results from the low level mercury sorbent test at the Oak Ridge Y-12 Plant in Tennessee. Author: Hollerman W, Holland L, Ila D, Hensley J, Southworth G, Klasson T, Taylor P, Johnston J, Turner R. Journal: J Hazard Mater; 1999 Sep 10; 68(3):193-203. PubMed ID: 10550710. Abstract: A mercury sorbent test was performed near the headwaters of the Upper East Fork Poplar Creek at the Oak Ridge Y-12 Plant in Tennessee. The sorbents SIR-200 (ResinTech), Keyle:X (SolmeteX), and GT-73 (Rohm and Haas) were the best materials tested for low level mercury removal. Each of these sorbents has a thiol-based active site. None of the tested sorbents reduced the mercury concentration to less than the existing 12 ng/l NPDES limit. For this small scale test, SIR-200, Keyle:X, and GT-73 reduced the mercury concentration to less than 51 ng/l, which is a regulatory treatment goal. The other sorbents tested, including granular activated carbon (Filtrasorb 300), did not reduce the mercury concentration below 51 ng/l at any tested flow up to 5 bed volumes per minute. Because of the cost and large volume of sorbent, a wastewater treatment plant for this stream would be prohibitively expensive to construct and maintain.[Abstract] [Full Text] [Related] [New Search]