These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Placement of left-sided double-lumen endobronchial tubes: comparison of clinical and fibreoptic-guided placement.
    Author: Cheong KF, Koh KF.
    Journal: Br J Anaesth; 1999 Jun; 82(6):920-1. PubMed ID: 10562789.
    Abstract:
    We have compared a new intubation manoeuvre using a fibreoptic bronchoscope with conventional blind placement of a double-lumen tube. Thirty adult patients who presented for thoracoscopy requiring one-lung ventilation underwent endobronchial intubation with a double-lumen tube inserted either in the conventional blind way or using a fibreoptic bronchoscope. There were four misplacements of the double-lumen tube using the conventional method but none using the bronchoscope. In addition, the bronchoscope allowed more rapid intubation (mean 106 vs 347 s). The results suggest that the fibreoptic-guided method of inserting the double-lumen tube was a satisfactory alternative to the conventional one.
    [Abstract] [Full Text] [Related] [New Search]