These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Comparison of the newly developed MB redox system with mycobacteria growth indicator tube (MGIT) and 2% Ogawa egg media for recovery of mycobacteria in clinical specimens].
    Author: Abe C, Hirano K, Wada M, Tsubura E, Yamanaka M, Aoyagi T, Osumi M, Takeda M, Kurashima A, Yoneyama A, Okuzumi K.
    Journal: Kekkaku; 1999 Oct; 74(10):707-13. PubMed ID: 10565130.
    Abstract:
    The rate of recovery and the mean time to detection of mycobacteria in clinical specimens were determined in a newly-developed MB Redox system based on liquid medium, and the results were compared with those of MGIT and 2% Ogawa egg media. From 587 sputum specimens processed, totally 203 mycobacterial isolates were detected, of which 177 (87.2%) with MB Redox, 185 (91.1%) with MGIT and 133 (65.6%) with 2% Ogawa medium. The difference in the percentages of positive cultures between either of the two liquid media and 2% Ogawa medium was significant (p < 0.0001). The mean time to detection of the Mycobacterium tuberculosis complex was 17.5 days with MB Redox, 18.7 days with MGIT, and 26.2 days with 2% Ogawa medium. The contamination rates were 1.5, 1.7, and 4.1% for MB Redox, MGIT, and 2% Ogawa medium, respectively. In conclusion, both MB Redox and MGIT systems, based on liquid medium, are more efficient than 2% Ogawa medium for the recovery of mycobacteria in clinical specimens.
    [Abstract] [Full Text] [Related] [New Search]