These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of gamma-hydroxybutyrate (GHB) in biological specimens by gas chromatography--mass spectrometry. Author: Couper FJ, Logan BK. Journal: J Anal Toxicol; 2000; 24(1):1-7. PubMed ID: 10654561. Abstract: A simple liquid-liquid extraction procedure for the analysis of gamma-hydroxybutyrate (GHB) in biological fluids without conversion to its lactone, gamma-butyrolactone, is described. Following derivatization to its di-TMS derivative, GHB was detected using gas chromatography-electron impact mass spectrometry. Diethylene glycol was used as the internal standard. The limit of quantitation in 1 mL of blood was 1 mg/L, and a linear response was observed over the concentration range 1 to 100 mg/L. Coefficients of variation for both intra-assay precision and interassay reproducibility ranged between 3.9 and 12.0%. GHB was detected in the blood of a sexual assault victim (3.2 mg/L), in the blood of two driving (DUI) cases (33 and 34 mg/L), and in the blood and urine of two nonfatal GHB-overdose cases (blood 130 and 221 mg/L; urine 1.6 and 2.2 g/L). The observed clinical symptoms ranged from confusion, disorientation, vomiting, and nystagmus to ataxia, sinus bradycardia, unconsciousness, and apnea.[Abstract] [Full Text] [Related] [New Search]