These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Flexor tendon repair using a stainless steel external splint. Biomechanical study on human cadaver flexor tendons.
    Author: Gordon L, Dysarz FA, Venkateswara KT, Mok AP, Ritchie RO, Rabinowitz S.
    Journal: J Hand Surg Br; 1999 Dec; 24(6):654-7. PubMed ID: 10672797.
    Abstract:
    A stainless steel external tendon splint was used in repair of cadaver tendons and compared with standard tendon repairs with suture. The splint was combined with a Kessler repair and tested against the Kessler, Becker, and Savage repairs in fresh human cadaver flexor digitorum profundus tendons. Biomechanical testing was done on a tensile testing machine, and load-displacement curves were generated. The repairs using the external tendon splint demonstrated a range of improvement of 32 to 146% in mean maximal tensile strength and a 20 to 185% improvement of mean ultimate tensile strength compared with all other repairs. The external tendon splint is relatively easy to apply to a tendon. The repair is strengthened and becomes capable of withstanding early active range of motion exercises. In vivo testing will be needed to assess the potential clinical usefulness of such a device.
    [Abstract] [Full Text] [Related] [New Search]