These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Influence of valve replacement on plasma endothelin-1 level in mitral stenosis. Author: Snopek G, Pogorzelska H, Korewicki J. Journal: J Heart Valve Dis; 2000 Jan; 9(1):82-7. PubMed ID: 10678379. Abstract: BACKGROUND AND AIM OF THE STUDY: The rise of pressure in the pulmonary circulation during the course of mitral stenosis leads to pathomorphological changes and a reduction in vascular compliance. Endothelial dysfunction is also promoted, with increased expression of endothelin. This aim of this study was to evaluate whether the increase in endothelin-1 levels in pulmonary hypertension due to advanced mitral stenosis is reversible after valve replacement. METHODS: Thirty-nine patients with isolated, longlasting post-rheumatic mitral stenosis were enrolled. During preoperative Swan-Ganz catheterization blood samples were withdrawn from the pulmonary artery and capillaries for measurement of endothelin-1 (ET-1). Similar examinations were performed six months after mitral valve replacement. Hemodynamic parameters were measured also during 25-W exercise effort. RESULTS: The mean preoperative hemodynamic parameters of the pulmonary circulation were moderately increased. Mean plasma levels of ET-1 were about three-fold higher than normal. Capillary levels of ET-1 were significantly higher than those in the pulmonary artery (1.78+/-1.22 versus 1.03+/-1.16 pg/ml, p <0.05). There was no significant correlation between ET-1 level and any hemodynamic or clinical parameters, except NYHA functional class. After surgery, pulmonary capillary levels of ET-1 fell significantly, but were still high (1.78+/-1.22 versus 1.41+/-1.00 pg/ml); ET-1 levels in the pulmonary artery were unchanged. Patients with persistently high ET-1 levels had significantly worse exercise hemodynamic parameters, especially of pulmonary arterial compliance. CONCLUSION: In patients with long-lasting, severe mitral stenosis, ET-1 levels remained increased and the ET-1 concentration gradient across the pulmonary circulation persisted for six months after valve replacement. High ET-1 capillary levels are correlated with poor exercise tolerance and poor exercise compliance of the pulmonary vessels.[Abstract] [Full Text] [Related] [New Search]